Product Description
Product FeaturesNote1
Innovative structure design & upgraded automatic operation
- Test cells with brand new pop-up drawer type design
- Automatic specimen clamping with uniform force
- Components are supplied by global well-known manufacturers, which are reliable and stable in performance
- Intelligent test mode, one-button test operation (test temperature should be set in advance) and automatic stop
- Scientific research mode provides more flexible parameter and function settings for analysis of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient
Upgraded testing accuracy and efficiency
- Imported high precision vacuum sensor for tests of ultra-high barrier property (0.01 0.09 cm3/ m224h0.1MPa) materials with high accuracy and repeatability
- Imported pneumatic control system with ultra-low failure rate and extremely long service life, which guarantees the seal performance of the whole system
- Imported high precision vacuum pump improves the evacuation efficiency and generates vacuum up to 0.2Pa
- The vacuum pump is turned on/off automatically
- For low and medium barrier property materials, test time is less than 4 hours (including evacuation time)
- For high barrier property materials, test time is less than 8 hours (including evacuation time)
- Three independent test cells provide individual test results, specimens can be replaced as desired
Excellent temperature and pressure control technique
- 360circulation constant temperature technology is applied in the instrument to remain the test temperature fluctuation below 0.05C
- Labthinks unique pressure compensation technique is used to maintain the stable differential pressure (pressure change is less than 0.2KPa)
- The pressure of high pressure chamber can be adjusted from 10KPa to 210KPa and maintained precisely
Versatile functions based on standards, customization available
- Various types of gases are testable: sole gas, mixed gases, poisonous gases, explosive gases and other dangerous gases (customization is required)
- The humidity of test gas can be adjusted and controlled automatically by the system, without requiring human intervention (customization is required for humidifying device)
- Labthinks unique data fitting function can provide the test results of gas transmission rate, permeability coefficient, solubility coefficient and diffusion coefficient at extreme temperatures
- Reference film for fast calibration ensures accurate and universal test data
- Calibration port for verifying test temperature and pressure
- Conform to the test standards of differential pressure method
High end, secure and easy-to-use embedded computer controlled system
- Integrated design of instrument and software minimizes the malfunctions caused by computer virus or faulty operations and ensures the performance of the instrument and data security
- The instrument can be easily operated with a mouse, a keyboard and a monitor. Windows operation interface for testing operations and displaying data
- The system is equipped with four USB ports and dual Internet ports for convenient data transmission
- The instrument meets the requirements of China GMP of pharmaceutical industry (optional)
- Labthinks unique DataShieldTM system for data management and connecting information management system (optional)
Test Principle
C130H is designed in accordance with differential pressure method. The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber.
Test StandardNote1
ISO 2556, ISO 15105-1, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003
ApplicationsNote1
This instrument is applicable to the determination of gas permeability of:
| Basic Applications |
- Films
Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
|
- Sheeting
Including engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
|
| Extended Applications |
- Various Gases
Test the permeability of various types of gases, e.g. O2, CO2, N2, Air and He
|
- Inflammable, Explosive and Poisonous Gases
Test the permeability of inflammable, explosive and poisonous gases
|
- Biodegradable Films
Test gas permeability of various sorts of biodegradable films, e.g. starch-based biodegradable bags
|
- Materials for Aerospace Usage
This instrument can test the Helium permeability of airship gas bags
|
- Paper and Paper Board
Test gas permeability of paper and paper-plastic composite materials, e.g. aluminized paper for cigarette packages, Tetra Pak sheeting, paper bowls for instant noodles and disposable paper cups
|
- Paint Films
Test gas permeability of substrates coated paint films
|
- Glass Fiber Cloth and Paper
Including glass fiber cloth and paper materials, e.g. Teflon paint cloth, Teflon welding cloth and Teflon silicon rubber cloth
|
- Soft Tube Materials for Cosmetics
Including various types of cosmetic tubes, aluminum-plastic tubes and toothpaste tubes
|
- Rubber Sheeting
Including various sorts of rubber sheeting, e.g. car tires
|
Technical SpecificationsNote2
| Specifications |
Film Test |
| Test Range |
0.01 50,000 cm3/m224h0.1MPa |
| Resolution |
0.001 cm3/ m224h0.1MPa |
| Temperature Range |
10C 50C (room temperature 23C) |
| Resolution |
0.01C |
| Temperature Fluctuation |
0.05C |
| Temperature Accuracy |
0.3C (calibration port) |
| Vacuum Resolution |
0.01Pa |
| Vacuum Accuracy |
Displayed Value 0.2% (1%100% of sensor range) |
| Vacuum Degree of Test Chamber |
< 10 Pa |
| Number of Specimens |
3 with independent test results Customization available for other number of specimens |
| Specimen Size |
97 mm |
| Test Area |
38.48 cm2 |
| Test Gas |
O2, N2, and CO2 (outside of supply scope) Humidifying of Test Gas (customization available) |
| Test Pressure |
10KPa 210KPa |
| Gas Supply Pressure |
0.5 Mpa 0.6 Mpa (73psi 87psi ) |
| Port Size |
6 mm PU Tubing |
| Instrument Dimension |
710 mm (L) 350 mm (W) 630 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
100 kg |
Configurations
- Standard Configurations
- Instrument, Monitor, Keyboard, Mouse, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump, 6 mm PU tubing (3m)
- Optional Parts
- GMP Computer System, DataShieldTM Note3, Air Compressor
- Note
- 1. The gas supply port of the instrument is 6 mm PU tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Measurement for Barrier FilmsThis permeability tester caters to high barrier, multilayer films, enabling simultaneous testing of up to three specimens. With a customizable test speed, wide measuring range, and advanced sensor technology, it delivers accurate, repeatable results crucial for product quality and compliance in critical industries such as pharmaceuticals, food packaging, and electronics.
Precision Control and ComplianceOperate within precisely controlled humidity and temperature conditions for dependable, traceable results. The tester meets international compliance requirements (ASTM F1249, ISO 15106, GB/T 26253) and features automatic calibration, guaranteeing accuracy that aligns with the highest industry benchmarks.
User-Friendly Data Management and SafetyBenefit from rapid response measurement, graphical/tabular outputs, and multi-format data export options. With built-in overtemperature protection and self-diagnostics, both equipment safety and operator assurance are integrated into its robust design. The system is ideal for laboratories requiring high throughput and detailed analysis.
FAQs of Optimizing Test Parameters for Reliable High Barrier Film Permeability Measurement:
Q: How do I set test parameters for different types of high barrier multilayer films?
A: Test parameterssuch as temperature, humidity, gas pressure, and test speedare fully programmable through the 7 touchscreen LCD. Operators can adjust these settings to match the specific properties and requirements of the barrier films being evaluated, ensuring accurate and relevant permeability measurements.
Q: What steps are involved in calibrating the Film Permeability Tester and how often is it needed?
A: Calibration is fully automatic and traceable to national standards, typically recommended once every 12 months. The system guides users through the calibration process via on-screen instructions, ensuring compliance and optimal measuring accuracy without requiring manual intervention.
Q: When should I export measurement data, and in what formats is it available?
A: Export measurement data as soon as test cycles are complete for analysis or compliance documentation. Data can be exported via USB, RS232, or Ethernet in graphical and tabular formats, compatible with standard analysis software, making it easy to integrate results into your reporting workflow.
Q: Where is this Film Permeability Tester most effectively used?
A: This tester is ideally suited for controlled laboratory environments in R&D, quality control, and industrial testingparticularly in the packaging, electronics, medical device, and materials fabrication sectors where precise control and documentation of film permeability are vital.
Q: What processes ensure the reliability of test results?
A: Reliability is achieved through features like isostatic or differential pressure testing methods, high-sensitivity multi-gas sensors, environmental control (1090% RH, 1050C), and automatic test parameter optimization. Built-in self-diagnostics and overtemperature protection further maintain data integrity and equipment safety.
Q: How is the test chamber material beneficial for high barrier film measurement?
A: The polished stainless steel chamber offers chemical resistance and an easy-clean surface, minimizing contamination and maintaining environmental stability. This ensures test consistency and data validity, especially when measuring permeability of sensitive or advanced barrier films.