Call Us
Send Inquiry
Seal Integrity Testing for Flow Wrapped Products

Seal Integrity Testing for Flow Wrapped Products

50000 USD ($)/Set

Product Details:

  • Test Range 0 - 9999 seconds
  • Application Seal integrity testing for flow wrapped products, pouches, sachets, and flexible packaging
  • Temperature 10C 40C
  • Mounting Type Table-top
  • Display Type Digital LCD display
  • Specimen Size 5 mm 300 mm wide
  • Operating Voltage 220V AC 10% 50/60 Hz
  • Click to View more
X

Seal Integrity Testing for Flow Wrapped Products Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set

Seal Integrity Testing for Flow Wrapped Products Product Specifications

  • 0 - 9999 seconds
  • Seal integrity testing for flow wrapped products, pouches, sachets, and flexible packaging
  • 10C 40C
  • Table-top
  • About 45 kg
  • 220V AC 10% 50/60 Hz
  • Digital LCD display
  • 5 mm 300 mm wide
  • 20% RH 70% RH
  • Semi-automatic
  • 0 5000 Pa (adjustable)
  • 220V, 50Hz
  • 50Hz
  • 150 mm
  • Microcomputer controlled
  • < 1 sec
  • 0 150 mm
  • 0.2 to 500 mm/min (adjustable)
  • Laboratory, Quality Control, R&D
  • 0.1 Pa
  • 0 - 5000 Pa
  • Automatic data recording, LED status indicators, customizable test parameters, user-friendly software
  • RS-232 (Communication/printing)
  • 0 - 350 mm
  • 6 mm pneumatic connector
  • 0.4 MPa 0.7 MPa (clean, dry air)
  • 1% of reading
  • 1

Product Description

Product FeaturesNote1

  • Ten (upper and lower) sealing jaws with metal surfaces to obtain heat sealing parameters that are close to actual parameters
  • Digital P.I.D. temperature control technology ensures the preset temperature to be reached rapidly without fluctuations
  • Auto constant pressure technology guarantees the stable sealing pressure, requiring no manual adjustment
  • Auto leveling technology of sealing jaws ensures uniform sealing performance
  • Wide range control of temperature, pressure and time that meet various test conditions
  • Manual or pedal switch, as well as anti-scald design provides convenient and safe operating environment
  • Professional software supports remote operation for convenient data saving, exporting and printing

Excellent User-oriented, High-efficient and Safe Designs

  • The instrument can complete 5 groups of specimen tests at a time, helps the user to obtain heat sealing parameters of the specimens accurately and efficiently.
  • The temperature of upper sealing jaws and lower sealing jaws can be controlled separately, which can meet the requirements for different combination of temperatures
  • Separated type sealing jaws can be easily replaced
  • Manual and pedal switch mode for starting test as well as the anti-scald design ensures the safe operation

High-end and Easy-to-Use Embedded Computer-controlled System

  • The instrument is equipped with large size tablet (touch screen), which is easy to operate and observe during the test process
  • Brand new software simplifies the testing process.
  • The system supports comparison analysis of groups of test data with unit conversion function
  • USB ports and internet interface for connecting of external device and data transmission
  • The instrument conforms to the requirements of GMP (optional)
  • Labthinks unique data security system separates the test data from the computer to avoid the risks caused by computer virus
  • Labthinks unique DataShiledTM System for data management and connecting with information system (optional)

Test StandardNote1

ASTM F2029, QB/T 2358, YBB 00122003

Applications

Basic Applications
  • Films with Smooth Surface
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others. Heat sealing surface should be smooth and width can be designed based on user requirements.
  • Films with Decorative Pattern Surface
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foil, aluminum foil composite films and many others. Heat sealing surface can be designed based on user requirements.
Extended Applications
  • Plastic Flexible Tubes
    The ends of plastic flexible tubes are placed in between upper and lower jaws and then sealed to form a package.

Technical SpecificationsNote2

Specifications C630H Heat Seal Tester
Sealing Temperature Room temperature 300C
Sealing Pressure 0.1Mpa 0.7 Mpa (14psi 101psi)
Resolution of Pressure 0.001 MPa
Dwell Time 0.1 999.99 s
Resolution of Time 0.01 s
Resolution of Temperature 0.1C
Temperature Fluctuation 0.2C
Temperature Accuracy 0.5C (single point calibration)
Temperature Gradient 20C
Gas Supply Pressure 0.7 Mpa (101psi)
Port Size 8 mm PU Tubing
Sealing Area 40 mm 10 mm
Number of Sealing Jaws 5 groups of upper and lower sealing jaws with independent temperature control
Instrument Dimension 375mm (L) 360 mm (W) 518mm (H)
Power Supply 220VAC 50Hz / 120VAC 60Hz
Net Weight 55 kg

Configurations

Standard Configurations
Instrument, Tablet, Pedal Switch, High-temperature Welding Cloth, Sample Cutter, 8mm PU Tubing (2m)
Optional Parts
High-temperature Welding Cloth, Air Compressor, GMP System, DataShieldTM Note3
Note
1. The gas supply port of the instrument is 8 mm PU Tubing;
2. Customers need to prepare gas supply.

Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Vacuum Generation for Reliable Seal Testing

Equipped with an in-built vacuum pump, this tester efficiently measures the integrity of seals on flow wrapped products, pouches, and flexible packaging. With fine-tuned control over vacuum pressure (up to 5000 Pa), operators can conduct burst, creep, and creep-to-fail tests for comprehensive quality evaluation. The system offers quick response times and ensures accuracy within 1% of the reading.


Wide Compatibility and User-Friendly Operation

This tester supports a diverse range of packaging materials, including plastic, foil, paper, and laminates. Its microcomputer-controlled system, digital LCD display, and customizable parameters offer seamless operation. The multi-language interface and memory for over 1000 results streamline workflow in international settings, while automatic data recording enhances traceability and efficiency.


Safety, Compliance, and Customization

Designed for safety, the tester features emergency stop and over-pressure protection. Standard fixtures are included, with custom accessory options available. The machine meets global compliance standards (ASTM F2054, F1140, ISO 11607), making it a reliable choice for exporters, manufacturers, and suppliers seeking robust, documented quality assurance.

FAQ's of Seal Integrity Testing for Flow Wrapped Products:


Q: How does the Seal Integrity Tester assess package seal strength?

A: The tester uses an in-built vacuum pump to perform burst, creep, and creep-to-fail tests, applying controlled air pressure to measure seal strength and detect leaks in flow wrapped products and flexible packaging.

Q: What types of materials can be tested using this equipment?

A: It is suitable for testing plastic, foil, paper, and laminate film packaging, making it versatile for a range of flexible packaging applications in laboratory and quality control settings.

Q: When should I choose manual versus automatic calibration?

A: Use automatic calibration for quick set-up and routine checks; opt for manual calibration if your protocols require specific verification or adjustment for compliance or validation purposes.

Q: Where can this tester be installed and used?

A: Designed as a table-top unit, it is ideal for use in laboratories, R&D facilities, and quality control departments across manufacturing, exporting, and supplying environments.

Q: What is the process for performing a test with this device?

A: After selecting the desired test mode, place the specimen (5-300 mm wide) in the fixture, set the parameters via the digital interface, and initiate the test-data is automatically recorded and can be exported or printed via the RS-232 interface.

Q: How does the device benefit quality control processes?

A: It enables accurate, repeatable seal integrity assessments, supports compliance with ASTM and ISO standards, and its high data storage and traceability features improve efficiency and reporting in regulated environments.

Q: What safety features are included with this tester?

A: The machine includes an emergency stop button and over-pressure protection to ensure safe operation during testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Heat Seal and Hot Tack Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.