Product Details:

  • Specimen Size 100 mm x 120 mm
  • Temperature Ambient to 50C
  • Max Height 450 mm
  • Test Range 0.01~10,000 cc/mday
  • Display Type LCD Digital Display
  • Operating Voltage AC 220V
  • Features Auto calibration, data logging, real-time monitoring
  • Click to View more
X

Heat Patch Oxygen Permeability Testing Instrument for Ensuring Optimal Performance Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Heat Patch Oxygen Permeability Testing Instrument for Ensuring Optimal Performance Product Specifications

  • 10%-90% RH (non-condensing)
  • 0.01 cc/mday
  • 6 mm gas inlet
  • Oxygen Permeability Testing Instrument
  • Benchtop
  • 50 Hz
  • Configurable, up to 50 mm/min
  • 0.1~0.3 MPa
  • 0-80 mm adjustable
  • AC 220V, 50Hz
  • 0.01 cc/mday
  • RS232 / USB
  • Semi-Automatic
  • Microprocessor-based digital control
  • 0.01 to 10,000 cc/mday
  • Measurement of oxygen permeability on heat patches and barrier films
  • Up to 3 simultaneously
  • Approximately 28 kg
  • <2 minutes
  • Up to 120 mm
  • Multiple sample chamber
  • Instrument Body: 75 Shore D
  • 100 mm x 120 mm
  • Ambient to 50C
  • 450 mm
  • 0.01~10,000 cc/mday
  • LCD Digital Display
  • Laboratory and industrial quality control
  • AC 220V
  • Auto calibration, data logging, real-time monitoring

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Oxygen Measurement Technology

Equipped with an electrochemical oxygen sensor and microprocessor-based digital control, this instrument delivers accurate and rapid measurements essential for quality assurance. Its LCD digital display facilitates real-time monitoring, while auto-calibration and comprehensive data logging streamline routine testing processes for both novice and experienced users.


Flexible Sample Handling and Chamber Design

The transparent polycarbonate chamber accommodates up to three specimens simultaneously and supports both manual and pre-cut sample preparation. With adjustable test speed and stroke, as well as a maximum test width of 120 mm, users can efficiently tailor analyses to suit distinct requirements, ensuring optimal coverage for diverse heat patch and film samples.


Robust Data Management and Safety Features

Effortlessly store and retrieve up to 2,000 test records with integrated RS232/USB connectivity for secure export. The system's audio-visual alarms promptly alert operators to abnormal readings, safeguarding both samples and equipment. The powder-coated steel body ensures durability, while automated calibration simplifies maintenance and promotes consistent results.

FAQ's of Heat Patch Oxygen Permeability Testing Instrument for Ensuring Optimal Performance:


Q: How does the oxygen permeability testing instrument work in measuring heat patch films?

A: The instrument uses an electrochemical oxygen sensor and a microprocessor-controlled environment to accurately measure the oxygen transmission rate through heat patch and barrier film samples. Test specimens are placed in a transparent chamber, and readings are digitally logged for analysis.

Q: What is the benefit of automatic calibration and data logging in quality control?

A: Automatic calibration ensures the device remains accurate with minimal user intervention, reducing the likelihood of human error. Data logging simplifies record-keeping, enables traceability, and allows for quick access to up to 2,000 stored records, supporting comprehensive quality audits.

Q: When should I use the audio-visual alarm system during testing?

A: The alarm system will automatically activate if abnormal readings are detected during testing. This immediate notification allows users to promptly address issues, preventing compromised results and equipment damage.

Q: Where can I use this instrument within industrial and laboratory environments?

A: The benchtop design makes it suitable for both laboratory and industrial quality control settings where oxygen permeability testing of heat patches and films is required. Its operating conditions range from 10C to 40C, with humidity support up to 85% RH.

Q: What is the process for preparing and mounting samples in the test chamber?

A: Samples can be prepared manually or using pre-cut sheets, sized up to 100 mm x 120 mm. The sample is placed in the transparent polycarbonate test chamber, which supports testing up to three specimens simultaneously, allowing for efficient throughput.

Q: How do the compliance standards benefit the validation of results?

A: Compliance with ISO 15105-2 and ASTM D3985 provides assurance that test methods and results align with recognized international standards, supporting reliable and globally accepted data for product development and regulatory approval.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.