Product Details:

  • Gas Pressure 0.6 MPa (max)
  • Number of Specimens 1~3 (independent tests)
  • Temperature 15C~55C adjustable
  • Features Auto temperature & humidity control, multi-unit support, data export
  • Humidity 10%~90% RH adjustable
  • Display Type 7-inch color touchscreen
  • Power Supply 220V, 50Hz
  • Click to View more
X

Assessing the Oxygen Barrier of Heat Patch Inner Packaging with Labthink Gas Permeability Tester Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set
  • Oxygen/Nitrogen (customizable)
  • Stainless steel
  • Over-range and fault alarms
  • Automatic & manual calibration
  • Coulometric sensor method (equal pressure) in accordance with ASTM D3985 and ISO 15105-2
  • ASTM D3985, ISO 15105-2, JIS K7126
  • Built-in memory, supports USB export
  • Coulometric sensor
  • Temperature: 5-35C, Humidity: 85%RH

Assessing the Oxygen Barrier of Heat Patch Inner Packaging with Labthink Gas Permeability Tester Product Specifications

  • 97 mm or 97 mm 97 mm
  • RS232, USB
  • Automatic
  • 6 mm
  • 100 mm
  • Touch screen/PLC automatic control
  • 15 seconds
  • 0.001 cc/m24h
  • Benchtop
  • 80 kg
  • 1% FS
  • Oxygen permeability analysis for heat patch inner packaging materials
  • AC 220V 10% 50Hz
  • 350 mm
  • 50 Hz
  • 0.05~5000 cc/m24h (standard film)
  • Oxygen Transmission Rate Tester
  • 0.05~5000 cc/m24h
  • 0~200 mm
  • 220V, 50Hz
  • 0.01~10 ml/min adjustable
  • Laboratory analysis for packaging oxygen barrier
  • 7-inch color touchscreen
  • 10%~90% RH adjustable
  • Auto temperature & humidity control, multi-unit support, data export
  • 15C~55C adjustable
  • Customizable
  • 1~3 (independent tests)
  • 0.6 MPa (max)
  • Oxygen/Nitrogen (customizable)
  • Stainless steel
  • Over-range and fault alarms
  • Automatic & manual calibration
  • Coulometric sensor method (equal pressure) in accordance with ASTM D3985 and ISO 15105-2
  • ASTM D3985, ISO 15105-2, JIS K7126
  • Built-in memory, supports USB export
  • Coulometric sensor
  • Temperature: 5-35C, Humidity: 85%RH

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Precision Oxygen Barrier Testing for Heat Patch Packaging

Labthink's Oxygen Transmission Rate Tester delivers reliable and accurate assessment of oxygen permeability in heat patch inner packaging. This instrument uses the coulometric sensor method and complies with international standards such as ASTM D3985, ISO 15105-2, and JIS K7126, ensuring trustworthy results for research, development, and quality control.


Advanced Automation and Data Management

The device features a fully automatic calibration system, touch screen/PLC automatic control, and robust over-range and fault alarms. With built-in memory, USB/RS232 export options, and adjustable test parameters for temperature, humidity, and flow rate, managing and analyzing test data becomes efficient and secure.


Versatile and User-Friendly Laboratory Tool

Designed for benchtop use, the tester is suitable for varying specimen sizes and can manage 1-3 independent samples simultaneously. Its customizable gas type (oxygen/nitrogen), quick response time, and intuitive color touchscreen display support a wide array of packaging analysis needs, making it perfectly suited for laboratory environments.

FAQ's of Assessing the Oxygen Barrier of Heat Patch Inner Packaging with Labthink Gas Permeability Tester:


Q: How does the Labthink Oxygen Transmission Rate Tester evaluate the oxygen barrier of heat patch inner packaging?

A: The tester measures the oxygen transmission rate (OTR) using a coulometric sensor method under equal pressure, in line with ASTM D3985 and ISO 15105-2. By placing packaging specimens in a temperature- and humidity-controlled stainless steel chamber and exposing them to oxygen or nitrogen gas, it accurately quantifies the oxygen permeability of the material.

Q: What are the main advantages of using this instrument for laboratory analysis?

A: This device provides high accuracy (1% FS), auto calibration, and multi-sample independent testing. With reliable temperature and humidity control, digital data management, swift response (15 seconds), and compliance with global standards, it offers efficient, repeatable, and trusted oxygen barrier assessments for packaging materials.

Q: When should I use this tester in the packaging development process?

A: Use this instrument during R&D, quality control, and routine inspection stages to verify the oxygen barrier properties of inner packaging materials for heat patches. Early testing can help optimize material selection and ensure compliance with both industry standards and product shelf-life requirements.

Q: Where is this equipment typically used?

A: This oxygen permeability tester is most commonly utilized in quality control laboratories, R&D departments of packaging manufacturers, exporting companies, and suppliers. Laboratories seeking precise, automatic, and standard-compliant results for heat patch packaging benefit greatly from its capabilities.

Q: What is the testing process with this oxygen transmission rate tester?

A: The process begins by preparing the specimen (97 mm or 9797 mm), which is placed in the stainless steel chamber. Test parameters such as temperature (15C~55C), humidity (10%~90% RH), and gas type are set via the touchscreen. The test runs automatically, with results displayed, stored, and exportable by USB or RS232 interface.

Q: How does the alarm and calibration system improve user experience?

A: The over-range and fault alarm functions notify operators of any deviations or malfunctions during testing, ensuring data integrity and instrument safety. Automatic and manual calibration options enable precise readings and continuous reliability without extensive manual intervention.

Q: What are the benefits of automatic temperature and humidity control during testing?

A: Automatic control of test temperature and humidity ensures consistent testing conditions, leading to reproducible and accurate results. This capability is crucial for packaging materials whose oxygen permeability may vary under different environmental conditions, thus supporting comprehensive and robust barrier analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.