Call Us
Send Inquiry    Call Me Free
Water Vapor Transmission Rate Testers for Textile

Water Vapor Transmission Rate Testers for Textile

50000 USD ($)/Set

Product Details:

  • Frequency 50 Hz
  • Number of Specimens 3 (standard) / 6 (optional)
  • Power Supply AC 220V, 50Hz
  • Specimen Size 74 mm
  • Max Height 480 mm
  • Humidity 30 90% RH adjustable
  • Interface Type RS232/USB
  • Click to View more
X

Water Vapor Transmission Rate Testers for Textile Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set

Water Vapor Transmission Rate Testers for Textile Product Specifications

  • 0.1 50,000 g/m24h
  • 10 100 mm adjustable
  • 1% of reading
  • 0.6 MPa
  • 15C 50C adjustable
  • Water Vapor Transmission Rate Tester
  • 0.01 g/m24h
  • Textile, Nonwovens, Technical Fabrics, Film Material
  • Automatic temperature and humidity control, Data storage, User-friendly interface
  • Automatic
  • Microcomputer Control
  • 30 kg
  • 1 10 cycles/min
  • 30 90% RH adjustable
  • 50 Hz
  • AC 220V, 50Hz
  • 3 (standard) / 6 (optional)
  • 74 mm
  • 480 mm
  • Bench-top
  • RS232/USB
  • Testing Water Vapor Transmission Rate in Textiles
  • 3 samples/batch
  • 6 mm
  • 0.1 50,000 g/m24h
  • 220V AC
  • 100 mm
  • <10s
  • LCD digital display

Product Description

Product FeaturesNote1

Infrared sensor

  • Equipped with Labthink patented infrared sensor, features a wider test range.
  • Designed conforming to ASTM F1249.
  • Ultra-long service life, non-consumable type.
  • Embedded with over-range warning and automatic protection function.

Accurate data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • The test chamber is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.
  • The control of velocity, temperature and relative humidity is automated to realize higher accuracy.

High Efficiency

  • Six independent test cells with a standard area of 50cm2, three times the number of test cells in traditional oxygen permeability testing instruments
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Within the same time duration, the number of tested specimens is increased from 2 to 6.
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click startup, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert.

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with various intelligent sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides oxygen transmission rate curve, oxygen transmission coefficient curve, temperature curve, and humidity curve.
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Ultra-wide temperature range to meet the barrier test under different extreme temperatures (optional).

Test Principle

The pre-conditioned specimen is clamped in the test cell, nitrogen with stable relative humidity flows on one side of the specimen while a stream of dry nitrogen flows on the other side. Due to the humidity difference, water vapor permeates through the specimen from the high humidity side into the low humidity side, and is carried to the infrared sensor by the dry nitrogen flow. By analyzing the electrical signals generated by the water vapor, the sensor calculates the water vapor concentration and the water vapor transmission rate.

Standard

ASTM F1249aISO 15106-2aGB/T 26253aJIS K7129aYBB00092003-2015

Applications

Applications
  • Films
    Water vapor transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others.
  • Sheets
    Water vapor transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C306H
Test range g/(m2day) (Standard area 50cm2) 0.02i40
g/(m2day) (MASK area 5cm2) 0.2i400i14Optionali14
g/(m2day) (MASK area 1cm2) 1i2000i14Optionali14
Resolution g/(m2day) 0.0001
Repeatability g/(m2day) 0.02 or 2%i14take the greater
Test Temperature 15i50i145i60i14Optionali14
Temperature fluctuation 0.15
Test Humidity %RHi14Within standard temperature rangei14 100%i145i902%
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 50cm2
Carrier Gas 99.999% High purity nitrogen(Outside of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 Metal tube
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System Requirement, DataShieldTM note3
Note The gas supply port of the instrument is I6 mm PU tubingi14pressure79.7 PSI / 550 kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Precise and Reliable Water Vapor Transmission Measurement

Engineered for accuracy, this tester offers a wide measurement range and resolution of 0.01 g/m224h. Automated calibration and microcomputer control guarantee repeatable results, ideal for research and quality assurance in textile and film production.


Convenient Operation and User-Focused Design

Its bench-top mounting, lightweight 30 kg frame, and user-friendly interface allow seamless integration into any laboratory. Automatic temperature and humidity controls, combined with rapid response times, simplify the testing process for operators.


Comprehensive Accessories and Compliance

Each tester includes sample cutters and desiccant cups for immediate testing setup, and the built-in PC software ensures all results meet ASTM E96 and GB/T 12704 standards. Data can be exported for analysis or archiving, assisting compliance and efficient documentation.

FAQ's of Water Vapor Transmission Rate Testers for Textile:


Q: How does the Water Vapor Transmission Rate Tester determine permeability in textiles?

A: This equipment utilizes the gravimetric/cup method, where the rate of water vapor passing through a sample is calculated by precise weight change measurements, ensuring compliance with ASTM E96 and GB/T 12704 standards.

Q: What materials are compatible with the Water Vapor Transmission Rate Tester?

A: It is designed for textiles, nonwovens, technical fabrics, and film materials, accommodating specimens with a diameter of 74 mm, typically tested using the three sample cups included in each batch.

Q: When is automatic calibration recommended during operation?

A: Automatic calibration should be performed before initiating a new test series or when switching specimen types to ensure the measurement accuracy remains within 1% of the actual reading.

Q: Where is the Water Vapor Transmission Rate Tester most effectively used?

A: This bench-top instrument is ideally suited for textile laboratories, manufacturing quality control centers, research facilities, and supplier environments where adherence to international standards is required.

Q: What is the process for conducting a water vapor transmission test using this equipment?

A: Samples are cut and placed in desiccant cups, which are then inserted into the chamber. The tester automatically controls temperature and humidity, records changes via its LCD display and software, and outputs results within 10 seconds response time.

Q: How can test results be exported for documentation or analysis?

A: The built-in PC software enables direct data export through RS232 or USB interface, allowing users to archive, analyze, and share results efficiently across platforms.

Q: What are the main benefits of using this tester for textile testing?

A: Benefits include precise, automatic measurements, rapid response time, adherence to global standards, user-friendly operation, and direct data management-all supporting optimized product development and quality monitoring.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.