Product Details:

  • Mounting Type Table Top
  • Frequency 50 Hz
  • Display Type Digital LCD Display
  • Interface Type RS232/USB
  • Equipment Type WVTR Tester
  • Measuring Range 0.01 ~ 10 g/m24h
  • Gas Pressure 0.6 MPa (maximum)
  • Click to View more
X

Water Vapor Transmission Rate (WVTR) Testing for Aluminium Papaer Packaging Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Water Vapor Transmission Rate (WVTR) Testing for Aluminium Papaer Packaging Product Specifications

  • 10% ~ 90% RH (controlled)
  • 50 mm
  • 15C ~ 50C (controlled)
  • 100 mm
  • Standard 8 mm
  • 220 V AC
  • Highly Sensitive Sensor, Integrated Humidity & Temperature Control, User-friendly Interface
  • AC 220 V, 50 Hz
  • 0.01 g/m24h
  • 400 mm (including chamber)
  • Water Vapor Transmission Rate Testing for Aluminium Paper Packaging
  • Laboratory and Industrial Testing
  • 80 mm
  • 0.001 g/m24h
  • 50 Hz
  • Digital LCD Display
  • Approx. 60 kg
  • RS232/USB
  • WVTR Tester
  • High Precision Test Chamber
  • Table Top
  • 0.6 MPa (maximum)
  • Automatic
  • Microcomputer Controlled
  • 3
  • Within 30 Seconds
  • 0.1 ~ 10 mL/min (adjustable)
  • 0.01 ~ 10 g/m24h
  • 0.01 ~ 10 g/m24h

Product Description

Product FeaturesNote1

Infrared sensor

  • Equipped with Labthink patented infrared sensor, features a wider test range.
  • Designed conforming to ASTM F1249.
  • Ultra-long service life, non-consumable type.
  • Embedded with over-range warning and automatic protection function.

Accurate data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • The test chamber is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.
  • The control of velocity, temperature and relative humidity is automated to realize higher accuracy.

High Efficiency

  • Six independent test cells with a standard area of 50cm2, three times the number of test cells in traditional oxygen permeability testing instruments
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Within the same time duration, the number of tested specimens is increased from 2 to 6.
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click startup, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert.

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with various intelligent sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides oxygen transmission rate curve, oxygen transmission coefficient curve, temperature curve, and humidity curve.
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Ultra-wide temperature range to meet the barrier test under different extreme temperatures (optional).

Test Principle

The pre-conditioned specimen is clamped in the test cell, nitrogen with stable relative humidity flows on one side of the specimen while a stream of dry nitrogen flows on the other side. Due to the humidity difference, water vapor permeates through the specimen from the high humidity side into the low humidity side, and is carried to the infrared sensor by the dry nitrogen flow. By analyzing the electrical signals generated by the water vapor, the sensor calculates the water vapor concentration and the water vapor transmission rate.

Standard

ASTM F1249aISO 15106-2aGB/T 26253aJIS K7129aYBB00092003-2015

Applications

Applications
  • Films
    Water vapor transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others.
  • Sheets
    Water vapor transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C306H
Test range g/(m2day) (Standard area 50cm2) 0.02i40
g/(m2day) (MASK area 5cm2) 0.2i400i14Optionali14
g/(m2day) (MASK area 1cm2) 1i2000i14Optionali14
Resolution g/(m2day) 0.0001
Repeatability g/(m2day) 0.02 or 2%i14take the greater
Test Temperature 15i50i145i60i14Optionali14
Temperature fluctuation 0.15
Test Humidity %RHi14Within standard temperature rangei14 100%i145i902%
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 50cm2
Carrier Gas 99.999% High purity nitrogen(Outside of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 Metal tube
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System Requirement, DataShieldTM note3
Note The gas supply port of the instrument is I6 mm PU tubingi14pressure79.7 PSI / 550 kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



High-Precision Testing for Packaging Integrity

WVTR testing is fundamental for manufacturers of aluminium paper packaging aiming to ensure optimal barrier properties against moisture. This apparatus delivers high sensitivity and accuracy, making it indispensable in quality control and research labs. With advanced sensor technology and tightly controlled test environments, users obtain dependable, repeatable results that guide packaging decisions and compliance with international standards.


Seamless Data Management and User Experience

Equipped with modern interface options such as RS232 and USB, the WVTR tester supports efficient data logging and report generation. Its user-centric design-featuring automatic microcomputer control and a clear digital LCD display-streamlines testing workflows and minimizes training requirements. Factory calibration ensures consistency, and user calibration is straightforward, promoting continued accuracy over time.

FAQ's of Water Vapor Transmission Rate (WVTR) Testing for Aluminium Papaer Packaging:


Q: How is water vapor transmission rate measured for aluminium paper packaging using this tester?

A: The WVTR Tester determines the moisture barrier performance of aluminium paper packaging by measuring the rate at which water vapor passes through a packaging material under controlled temperature and humidity, following ASTM E96 and ISO 2528 standards. The integrated infrared/coulometric sensor quantifies the vapor, and the process is managed through a microcomputer for precise control and automatic operation.

Q: What are the preparation steps and process for running a WVTR test?

A: To perform a test, specimens of 80 mm size are placed in the stainless steel chamber. Conditions for temperature (15C-50C) and humidity (10%-90% RH) are set via the control panel. The test is initiated from the digital interface, with adjustable test speed and stroke. Data is captured by the sensor and can be logged or printed for records.

Q: When should the WVTR tester be calibrated?

A: The WVTR tester comes factory calibrated to international standards. Nonetheless, periodic user calibration is recommended to maintain high accuracy (0.01 g/m224h). The calibration frequency often depends on usage intensity and laboratory protocols but is generally advisable before major testing campaigns or after extended periods of inactivity.

Q: Where can this WVTR tester be effectively utilized?

A: This equipment is designed for laboratory and industrial environments, accommodating needs in quality control, research, and manufacturing settings. It's suitable for exporters, manufacturers, and suppliers in packaging industries, particularly those working with aluminium foil, paper laminates, and composite materials.

Q: What materials does the tester accommodate and what are the typical applications?

A: The tester is compatible with aluminium foil, paper laminates, and composite films, making it ideal for evaluating packaging materials used in the food, pharmaceutical, and industrial sectors. It helps assess barrier integrity, shelf-life prediction, and compliance with regulatory standards.

Q: How is data managed, and what output options are available?

A: Test data can be viewed in real time on the digital LCD display and exported to a PC using RS232 or USB interfaces. Users can log tests, maintain electronic records, and generate printouts, facilitating traceability and easy reporting for audits or quality management systems.

Q: What are the main benefits of using this specific WVTR tester?

A: The key benefits include highly sensitive, rapid, and accurate moisture barrier assessment, user-friendly automated operation, integrated humidity and temperature control, robust stainless steel construction, wide measuring range, and seamless data handling. These advantages ensure efficient quality control and compliance with ASTM and ISO standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.