Product Description
Product FeaturesNote1
Coulometric Oxygen Sensor
- The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
- Designed according to ASTM D3985 with absolute value and no need to calibrate.
- Super long service life, three times longer than traditional Coulometric oxygen sensor.
- Functions of over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
- In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
Effective Three-Cell
- Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
- Three samples are tested at the same time under the same condition, and the data are independent.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
- Safe Performance: the instrument uses global famous brand with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
- Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
- Ultra wide test range, meet the barrier test (customized) of various materials.
- Ultra wide temperature range, meet the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).
Testing Principle
The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.
Reference Standards
ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Applications
| Applications |
- Films
The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
|
- Sheet
The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Parameters
Table 1: Test Parameters Note2
| Parameters/Model |
C203H |
| Test Scope |
cc/(m2day) (standard area 50cm2) |
0.01i200 0.005i200 (optional) |
| cc/(m2day) (standard area 50cm2) |
0.01i400000i14Customizei14 |
| cc/(m2day) (MASK area 5cm2) |
0.12000 (optional) |
| cc/(m2day) (MASK area 1cm2) |
0.510000 (optional) |
| Resolving Power |
cc/(m2day) |
0.0001 |
| Repeatability |
cc/(m2day) |
0.01 or1%, whichever is greater |
| Temperature Range |
|
15i50 560 (customized) |
| Temperature Fluctuation |
|
0.05 |
| Humidity Range |
%Rh (within standard temperature range) |
O2: 0%i145i901% Carrier Gas: 0%, 5i902% |
| Extended Functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Data Shield Note 3 |
Optional |
| GMP Computer System Requirements |
Optional |
| CFR21Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 sets |
| Sample Size |
4.4 x 4.4i1411.2cm11.2cmi14 |
| Sample Thickness |
120 Mili143mmi14 |
| Standard Test Area |
50cm2 |
| Gas Specification |
99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer) |
| Air Source Pressure |
40.6 PSI / 280 kPa |
| Interface Size |
1 / 8 "metal tube |
| Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Power Supply |
120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two) |
| Instrument Dimension |
23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm) |
| Net weight |
220Lbs(100kg) |
Table 3: Product Configuration
| Standard Configuration |
Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
| Options |
Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements DataShieldTM Data ShieldNote3 |
| Remarks |
The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer. |
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.
High-Precision Oxygen Permeability MeasurementEquipped with an advanced coulometric sensor, the instrument guarantees accurate and consistent oxygen barrier detection across a broad measurement range (0.01-50,000 cc/m224h). It rapidly delivers results within five minutes, making it suitable for time-sensitive laboratory environments and reliable packaging material analysis. The robust stainless steel chamber resists corrosion and maintains integrity over years of intensive lab use.
Convenient Workflow and Automated FeaturesManual sample placement enables quick loading of packaging specimens of various sizes (50 mm 50 mm to 150 mm 150 mm). Testing is fully automated, and the system supports up to three specimens analyzed in parallel, boosting laboratory throughput. Calibration is performed automatically using standard gases, ensuring continuous accuracy and minimal intervention.
Comprehensive Data Management and SafetyWith the ability to store 1000 historical test records, labs can archive and retrieve results efficiently. LCD touch screen offers intuitive navigation in multiple languages. Over-temperature, over-pressure, and sensor fault alarms protect operators and equipment, while automatic temperature and humidity controls maintain precise test conditions.
FAQ's of Oxygen Barrier Properties Testing Instrument:
Q: How does the Oxygen Barrier Properties Testing Instrument ensure accurate permeability measurement?
A: This device utilizes a high-precision coulometric (galvanic) sensor renowned for its sensitivity and stability. Automatic calibration with standard gas keeps readings reliable and precise within an accuracy of 0.01 cc/(m224h0.1MPa).
Q: What types of samples and sizes are compatible with this instrument?
A: You can test packaging films, foils, and laminates within specimen size ranges from 50 mm 50 mm to 150 mm 150 mm. The chamber supports up to three samples simultaneously for parallel analysis.
Q: When should calibration be performed, and is it manual or automatic?
A: Calibration is automatic and occurs using standard gases, ensuring the instrument remains accurate before testing or at manufacturer-set intervals, reducing user intervention and potential error.
Q: Where is the Oxygen Barrier Properties Testing Instrument best utilized?
A: This instrument is ideally suited for laboratory settings focused on packaging quality assurance, research, or compliance tests, benefiting exporters, manufacturers, and suppliers in the material industry.
Q: What is the process for conducting a permeability test with this equipment?
A: Operators manually place samples in the chamber, select test parameters on the LCD touch screen, and start the fully automatic test. Real-time oxygen permeability curves and environmental data are displayed and stored for review.
Q: How does the system protect users and maintain safe operation?
A: Multiple alarms, including over-temperature, over-pressure, and sensor fault notifications, safeguard both operators and equipment; automatic environmental controls further prevent test anomalies.
Q: What are the benefits of using this oxygen barrier testing instrument for packaging analysis?
A: Users benefit from rapid, reliable results, parallel multi-sample analysis, efficient data management, reduced manual oversight due to automation, and compliance with internationally recognized standards, optimizing both testing efficiency and data integrity.