Call Us
Send Inquiry Send SMS
Equal Pressure Methods Film Gas Permeability Measuring System

Equal Pressure Methods Film Gas Permeability Measuring System

50000 USD ($)/Set

Product Details:

  • Test Range 0.01-1000 cc/m2day
  • Gas Pressure 0.02-0.3 MPa adjustable
  • Resolution 0.001 cc/m2day
  • Power Supply AC 220 V 10%, 50 Hz
  • Features High precision, Multi-channel, User-friendly interface, Real-time data output
  • Accuracy 1% of reading
  • Display Type Touch screen digital display
  • Click to View more
X

Equal Pressure Methods Film Gas Permeability Measuring System Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Equal Pressure Methods Film Gas Permeability Measuring System Product Specifications

  • USB, RS232
  • 450 mm
  • 15-50C adjustable
  • 38 kg
  • 2 s
  • Automatic
  • Microcomputer controlled
  • 220 V
  • Film Gas Permeability Measuring System
  • Benchtop
  • Up to 3 specimens simultaneously
  • 0.001 cc/m2day
  • AC 220 V 10%, 50 Hz
  • 0.02-0.3 MPa adjustable
  • 0.01-1000 cc/m2day
  • 1% of reading
  • Variable depending on mode
  • Maximum 100 mm
  • High precision, Multi-channel, User-friendly interface, Real-time data output
  • 100 mm 100 mm
  • Standard interface
  • Measurement of gas permeability in plastic film, composite film, high barrier film, sheet materials
  • Touch screen digital display
  • 0.01-1000 cc/m2day
  • 30-90% RH adjustable
  • 0-350 mm
  • 50 Hz
  • 0.01-10 mm/min adjustable
  • Film testing laboratory, R&D, Quality control

Product Description

Product FeaturesNote1

Coulometric Sensor

  • Equipped with Labthink latest technology ppb-level coulometric sensor features a wider test range.
  • Designed conforming to ASTM D3985, intrinsic standard and no calibration is required.
  • Ultra-long service life which three times that of traditional oxygen coulometric sensor.
  • Embedded with over-range warning and automatic protection function.

Accurate data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • The test chamber is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.
  • The control of air flow, temperature and relative humidity is automated to realize higher accuracy.

High Efficiency

  • Six independent test cells with a standard area of 50cm2, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Within the same time duration, the number of tested specimens is increased from 2 to 6.
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated
  • Intelligent test chamber hood automatically opens and closes with sound and light alert.

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides oxygen transmission rate curve, oxygen transmission coefficient curve, temperature curve, and humidity curve.
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Ultra-wide temperature range to meet the barrier test under different extreme temperatures (optional).
  • The gas purifier independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen-free carrier gas (optional).

Test Principle

The pre-conditioned specimen is clamped in the test cell, oxygen or air flows on one side of the specimen while a stream of high purity nitrogen flows on the other side. Oxygen molecules permeate through the specimen into the nitrogen side and are carried to the coulometric sensor. The sensor analyzes the oxygen concentration and calculates the oxygen transmission rate and other factors.

Standard

ASTM D3985aASTM F1307aGB/T 19789aGB/T 31354aDIN 53380-3aJIS K7126-2-BaYBB 00082003-2015

Applications

Applications
  • Films
    Oxygen transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Oxygen transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C206H
Test range cc/(m2day) (Standard area 50cm2) 0.02i200
cc/(m2day) (Standard area 50cm2) 0.02i400000i14Customizei14
cc/(m2day) (MASK area 5cm2) 0.2i2000i14Optionali14
cc/(m2day) (MASK area 1cm2) 1i10000i14Optionali14
Resolution cc/(m2day) 0.0001
Repeatability cc/(m2day) 0.02 or 1%i14take the greater
Test Temperature 15i50i145i60i14Optionali14
Temperature fluctuation 0.15
Test Humidity %RHi14Within standard test temperature rangei14 0%i145i902%
Additional Functions GP-01 Gas Purifier Optional
DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.4 x 4.4i1411.2cm11.2cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 50cm2
Gas supply 99.999% Nitrogena99.5% Oxygeni14 Outside of supply scopei14
Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 Metal tube
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, sampler, vacuum grease, I6 mm PU tubing
Optional Parts GP-01 Gas Purifier, Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas supply port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters"
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Precise Multi-Gas Permeability Testing

Engineered to measure the permeability of various gases-including oxygen, nitrogen, and carbon dioxide-this system employs the equal pressure method for reliable, repeatable results. Its stainless steel test chamber ensures consistent performance across film types, making it an essential tool for comprehensive material analysis.


Intuitive Operation & Advanced Analysis

Featuring a touch screen digital display and built-in microcomputer control, the system offers instant access to settings, test progress, and data visualization. The included analysis software provides advanced graphing, customizable reports, and seamless data export via USB, simplifying laboratory workflows.


Robust Safety and Automation

This instrument delivers automatic calibration and manual adjustment capabilities, paired with over-pressure protection and auto-stop safety functions. Ambient conditions are managed with adjustable temperature and humidity controls, allowing for flexible use in diverse laboratory environments.

FAQ's of Equal Pressure Methods Film Gas Permeability Measuring System:


Q: How does the Equal Pressure Method work in gas permeability testing?

A: The system operates by maintaining equal pressure on both sides of the film specimen, measuring the flow of gases such as oxygen, nitrogen, or carbon dioxide through the material. The microcomputer continually records and analyzes permeability rates, delivering precise, repeatable results.

Q: What types of gases can be tested with this Film Gas Permeability Measuring System?

A: It supports testing with oxygen, nitrogen, carbon dioxide, and other common test gases, catering to a wide variety of film materials and application requirements.

Q: When should automatic and manual calibration be performed?

A: Automatic calibration is recommended for routine tests, ensuring consistent accuracy. Manual calibration can be used for specialized tests, or when fine-tuning is required due to unique specimen characteristics or environmental factors.

Q: Where is this system primarily used?

A: This system is ideally used in film testing laboratories, R&D departments, and quality control environments where precise measurement of gas permeability in films and sheet materials is required.

Q: What is the process for conducting a test using this system?

A: After placing up to three specimens (100 mm 100 mm each) into the stainless steel chamber, users adjust parameters via the touch screen interface. The system runs tests at adjustable speeds, automatically collects and stores data, and provides in-depth analysis with included software.

Q: How does data storage and analysis work on this instrument?

A: All test data are stored internally and can be easily exported via USB. The advanced analysis software allows users to generate graphs and tailored reports, facilitating efficient data interpretation and documentation.

Q: What are the main benefits of using this gas permeability measuring system?

A: Benefits include high precision measurement (accuracy 1% of reading), multi-channel testing for up to three specimens, automated and user-friendly operation, robust safety controls, and advanced data analysis-all contributing to reliable and efficient laboratory workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.