Call Us
Send Inquiry Send SMS
Differential Pressure Method 6-cell Film Gas Permeability Test System

Differential Pressure Method 6-cell Film Gas Permeability Test System

50000 USD ($)/Set

Product Details:

  • Port Size Standard (6 test cells)
  • Automation Grade Fully Automatic
  • Display Type Touchscreen LCD
  • Operating Voltage 220V AC
  • Temperature 15C50C programmable
  • Power Supply AC 220V, 50Hz
  • Number of Specimens Up to 6 simultaneously
  • Click to View more
X

Differential Pressure Method 6-cell Film Gas Permeability Test System Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Differential Pressure Method 6-cell Film Gas Permeability Test System Product Specifications

  • 0.01 cm/m24h
  • Film Gas Permeability Tester
  • 0.0110 ml/min adjustable
  • USB, Ethernet
  • 20%90% RH adjustable
  • Approx. 75 kg
  • Measurement of gas permeability of films, foils, and sheets
  • Benchtop
  • 1% FS
  • 480 mm
  • 0.015000 cm/m24h0.1MPa
  • Automatic temperature & humidity control, Multi-cell testing, Data export, Safety interlock, Real-time monitoring
  • 50/60 Hz
  • 0.015000 cm/m24h0.1MPa
  • 0100 mm
  • 6 test chambers
  • 220V AC
  • 15C50C programmable
  • AC 220V, 50Hz
  • Up to 150 mm
  • Film, packaging, and food industry laboratory testing
  • Touchscreen LCD
  • 97 mm diameter
  • Up to 6 simultaneously
  • 0.010.1 MPa
  • 2 seconds
  • Standard (6 test cells)
  • Microcomputer Control, Touchscreen Operation
  • Fully Automatic

Product Description

Product FeaturesAccurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.
  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.
  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert
  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.
  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.
  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

High Efficiency

Intelligent control

Safe and reliable

Space saving

Powerful functions

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Multi-Cell Film Gas Permeability Testing

This system facilitates concurrent testing of up to six film specimens, increasing laboratory productivity. Its compliance with international standards like ISO 15105-1 and ASTM D1434 allows for comprehensive and accurate gas permeability measurements under various environmental conditions. The automatic calibration and built-in leak detection further enhance test reliability and consistency.


Precision Control with Intuitive Operation

Equipped with a touchscreen LCD and microcomputer control, the tester offers automatic temperature and humidity regulation (15C-50C, 20%-90% RH), real-time monitoring, and quick response time (2 seconds). Users can easily program test conditions, manage data, and monitor safety alarms for over-temperature or over-pressure situations, ensuring seamless and safe operation.


Versatile Data Management and Export

Large-capacity internal memory stores extensive test results, which can be exported via USB or Ethernet. The system outputs key metrics such as Gas Transmission Rate (GTR) and Permeability Coefficient. This facilitates data analysis and reporting for quality assurance, research, or product development in film, packaging, and food industries.

FAQ's of Differential Pressure Method 6-cell Film Gas Permeability Test System:


Q: How does the differential pressure method function in this test system?

A: The differential pressure method measures gas transmission through a film by applying a set pressure difference across it. The system detects the permeated gas volume in real time, providing accurate gas transmission rates (GTR) and permeability coefficients, as per ISO 15105-1 and ASTM D1434.

Q: What specimen sizes and materials can be tested with this system?

A: The tester accommodates film, foil, and sheet specimens with a diameter of up to 97 mm and a test width up to 150 mm. It is ideal for use in laboratories focused on packaging, food industry materials, and research on gas barrier properties.

Q: When should I recalibrate or check for leaks in the system?

A: Calibration and leak detection are managed automatically by the device before each test sequence, ensuring consistent accuracy (1% FS) and reliability. Users are notified via the touchscreen display if intervention is required.

Q: Where is the system best installed for optimal performance?

A: The tester is designed for benchtop mounting within a controlled laboratory environment operating between 5C-35C and 85% RH. Adequate ventilation, stable power supply (AC 220V, 50/60 Hz), and clear space for the machine (75 kg, up to 480 mm high) ensure optimal function.

Q: What is the process for exporting data from the test system?

A: After testing, all measured results, including GTR and permeability coefficients, are stored in the internal memory. Data can then be easily exported to a computer or storage device via USB or Ethernet for further analysis or archiving.

Q: How do the safety features benefit laboratory operation?

A: The system includes real-time monitoring, over-temperature and over-pressure alarms, and a safety interlock mechanism. These features protect both the equipment and operators, while automatic shut-off during abnormal conditions ensures safe, reliable testing cycles.

Q: What advantages does multi-cell testing provide for laboratories?

A: With up to 6 simultaneous specimen testing, laboratories can significantly boost throughput, minimize operator intervention, and maintain consistent environmental conditions across multiple samples. This efficiency is especially valuable for comparative or high-volume testing projects.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.