Product Description
Product FeaturesNote1
Ten Test Modes to Meet Various Testing Demands
- Ten independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, puncture test of rubber closure and puncture retention force test, etc. at users choice
- The instrument supports bidirectional testing modes, which can be used for puncture test of rubber closure and breaking force test of ampoule and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- The instrument is integrated with software requiring no external computer
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610M is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical Specifications
| Specifications |
C610M Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) 5N (Customization available) |
| Accuracy |
0.5% of indicated value (2%FS 100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0500 mm/min |
| Speed Accuracy |
0.5% of indicated value |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 MPai1472.5psii101.5psii14 |
| Stroke |
950 mm (customization available for 1200mm) |
| Instrument Dimension |
450 mm (L) x 450 mm (W) x 1410 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
95 kg |
Configurations
- Standard Configurations
- Instrument (with embedded software), LCD Monitor, Keyboard, Mouse, Pneumatic Sample Girps
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Air Compressor
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Optimized for Multi-Sample TestingThis equipment can simultaneously test up to six tape specimens, boosting productivity in quality control processes. The 25 mm width and 120 mm stroke accommodate a wide variety of adhesive tapes, while the microprocessor-based control ensures consistent and repeatable test results. With a rapid standard test speed of 300 mm/min (adjustable), even large samples can be processed efficiently.
Compliant, Accurate, and SafeDesigned to meet ASTM D3654, PSTC-7, and ISO 29862 standards, this tester offers 1% reading accuracy within a 0-10 kg range and a fine 1 g resolution. Built-in safeguards include an audible alarm for test completion or errors, overload protection, and a powder-coated corrosion-resistant body, ensuring long-term durability and operator safety. Push-button calibration helps maintain precision with minimal effort.
FAQ's of Tape Shear Strength Testing Equipment:
Q: How does the Tape Shear Strength Testing Equipment operate for different clamping needs?
A: The equipment supports both manual and pneumatic clamping methods, allowing users to select the most suitable option for their adhesive tape type and testing protocols. This flexibility enhances reliability and repeatability in results.
Q: What is the primary benefit of using this equipment for adhesive tape testing?
A: Its main advantage is high-throughput, accurate measurement of tape shear strength, supporting up to six samples tested simultaneously, with precise digital readout and integrated data storage for quality assurance and compliance verification.
Q: When should calibration of the equipment be performed, and how is it done?
A: Calibration should be performed regularly, especially before critical testing sessions, to ensure measurement accuracy. The equipment simplifies this process through a user-friendly push-button calibration system that guides operators efficiently.
Q: Where is the Tape Shear Strength Tester typically used?
A: This device is widely utilized in laboratories and industrial quality control settings, especially in adhesive manufacturing, packaging, and related sectors for compliance testing and product development.
Q: What is the process for running a shear strength test using this device?
A: After specimen preparation (25 mm 75 mm), the tape is mounted on the stainless steel test plate. Selection of test parameters such as load, timer range, and clamping method precedes the test, which is then initiated via the digital interface. Data is automatically recorded and an alarm signals completion or any errors.
Q: What data output and storage features are available with this tester?
A: The tester includes integrated memory for up to 1,000 test results and supports both RS232 and USB interfaces for exporting data to external devices, enabling effortless documentation and traceability.
Q: What safety features protect the user and equipment during testing?
A: For user safety, the device includes an audible alarm for test completion or fault detection and overload protection to prevent damage to both specimens and the equipment itself. Its powder-coated finish provides added corrosion resistance.