Product Description
Product FeaturesNote1
Innovative Laser Measurement Technology providing Higher Precision and Efficiency
- Advanced laser measurement technology, measures thermal shrinkage ratio of film precisely
- High precision load cell supplied by global renowned manufacturer, provides testing accuracy higher than 0.5%FS and better repeatability of test results
- Multiple test ranges can be selected to meet various testing requirements
- Global renowned brand operating control system guarantees the accuracy of displacement and speed
- Three speeds (up to 2 seconds) for loading specimen can be selected
- Shrinking force, contracting force and shrinkage ratio are displayed in real time
Embedded, Secured and Easy-to-use Computer Controlled System
- Integrated design of instrument and software requires no external computer
- Standard monitor, mouse, keyboard and Window operating interface for simplified operation and data display
- Historical data can be reviewed and printed
- USB ports and net ports for external connection and data transmission
- Intelligent reminder for sensor calibration provides safe data processing environment
- Labthinks unique data security design isolates the test data from computer and prevents data loss caused by computer virus
- Labthinks unique DataShiledTM System for data management and connecting with information system (optional)
Test Principle
The specimen is placed in the test area for displacement and force measurement, it is then heat to the specified temperature for shrinkage test and cooled down. The system automatically records the shrinking force, temperature and shrinkage ratio in real time and provides analytical results.
Test StandardNote1
GBT34848, ISO-14616-1997, DIN 53369-1976
Applications
| Basic Applications |
- Shrinking Force & Contracting Force
Measure the shrinking force and contracting force of heatshrinkable film under specific conditions
|
- Shrinkage Ratio
Measure the shrinkage ratio of heatshrinkable film under specific conditions
|
Technical SpecificationsNote2
| Specification |
C631H |
| Load Cell Capacity |
5 N (Standard) 10 N, 30 N (Optional) |
| Force Accuracy |
Indicated Value 0.5% (10%-100% of Load Cell Capacity) 0.05%FS (0%-10% of Load Cell Capacity) |
| Force Resolution |
0.001 N |
| Displacement Range |
0.1 95 mm |
| Displacement Accuracy |
0.1 mm |
| Shrinkage Ration Range |
0.1%95% |
| Temperature Range |
Room Temperature 210C |
| Temperature Variation |
0.2C |
| Temperature Accuracy |
0.5C (Single Point Calibration) |
| Number of Stations |
1 Group (2 pcs) |
| Specimen Size |
110 mm 15 mm (Standard) |
| Instrument Dimension |
480 mm (L) 400 mm (W) 630 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
26 kg |
Configurations
- Standard Configurations
- Instrument, Monitor, Mouse, Keyboard, High-temperature Welding Cloth, T-Plate (10 pcs)
- Optional Parts
- High-temperature Welding Cloth, T-Plate, DataShieldTM Note3
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Film Testing PrecisionEngineered for accuracy, this equipment offers a wide measuring range (0-400N) and a high resolution (0.01N), ensuring that quality control teams can precisely evaluate film durability and consistency. Its standard weight calibration system and rapid response time (0.5s) enhance measurement reliability for every test.
Intuitive Operation and VersatilityWith a digital LCD display, touch-screen interface, programmable settings, and microcomputer controls, the machine simplifies operation for users. Compatible with Windows 7/8/10, the system accommodates up to five specimens at once, making it suitable for high-throughput environments in laboratories and manufacturing.
Unmatched Safety and Data ManagementSafety is prioritized through features like emergency stop and overcurrent protection. Extensive data acquisition, USB and RS-232 outputs, and multi-language support streamline reporting and minimize manual entry, supporting efficient record-keeping for every film test.
FAQ's of Chemical Packaging with Heat Shrinkable Film Testing Solution:
Q: How does the Heat Shrinkable Film Testing Machine conduct film tests for chemical packaging?
A: The machine uses thermal shrinkage and tensile testing methods to evaluate heat shrinkable films. Specimens are quickly prepared (under 2 minutes), and the programmable system executes tests like shrinkage and mechanical strength, providing accurate measurements via a digital display.
Q: What types of film and specimen sizes are supported by the equipment?
A: It supports film thicknesses between 10 and 200 microns, with specimen sizes up to 250mm x 25mm. The system accommodates up to five specimens per cycle and is compatible with films up to 50 Shore D hardness, allowing versatile usage in chemical packaging assessment.
Q: When is calibration required, and how is it performed?
A: Calibration should be conducted periodically or after significant use to maintain accuracy. The machine features a standard weight calibration mechanism, ensuring consistent measurement precision within 0.5% of the reading.
Q: Where can this device be used within industrial or laboratory setups?
A: Designed for bench-top mounting, the Heat Shrinkable Film Testing Machine is suitable for quality control laboratories and industrial production lines involved in chemical packaging. Its robust build and automated operation make it adaptable to various testing environments.
Q: What is the process for storing and exporting test data?
A: After testing, the system can automatically store up to 2,000 records. Users can export data conveniently using USB or RS-232 interfaces, ensuring compatibility with laboratory management systems and facilitating detailed reporting.
Q: How does the equipment enhance safety during operation?
A: It is equipped with emergency stop functionality and overcurrent protection to safeguard users and equipment during unexpected events, promoting safe handling throughout the testing process.
Q: What are the primary benefits of using this testing solution for chemical packaging films?
A: Users benefit from rapid sample processing, high measurement accuracy, flexible test programming, and robust data management capabilities. These features streamline quality assurance protocols, reduce manual workload, and support compliance with industry standards.