Call Us
Send Inquiry Send SMS
Packaging Oxygen and Water Vapor Permeation Testing System for Diverse Industries

Packaging Oxygen and Water Vapor Permeation Testing System for Diverse Industries

50000 USD ($)/Set

Product Details:

  • Mounting Type Bench-top
  • Max Height 450 mm
  • Test Range 0.0550,000 cc/(m24h0.1MPa), 0.05500 g/(m24h)
  • Display Type LCD Touch Screen
  • Features High precision, automatic data storage, multi-point calibration
  • Interface Type RS232/USB
  • Frequency 50 Hz
  • Click to View more
X

Packaging Oxygen and Water Vapor Permeation Testing System for Diverse Industries Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set

Packaging Oxygen and Water Vapor Permeation Testing System for Diverse Industries Product Specifications

  • 0.001 cc/(m24h0.1MPa), 0.001 g/(m24h)
  • Approx. 100 kg
  • Film, packaging, pharmaceutical, food, electronics, and other industries
  • 0.01 cc/(m24h0.1MPa), 0.01 g/(m24h)
  • Oxygen & Water Vapor Transmission Rate Testing System
  • 1/4 inch NPT
  • 97 mm or customized
  • Fully Automatic
  • 10%~98% RH (Adjustable)
  • Oxygen/water vapor transmission rate test
  • AC 220V 10%, 50Hz
  • 0.0550,000 cc/(m24h0.1MPa), 0.05500 g/(m24h)
  • 220V 50Hz
  • Multiple modules as required
  • 13 (simultaneous measurement)
  • Adjustable, up to 200 mm/min
  • 0.30.6 MPa
  • High precision, automatic data storage, multi-point calibration
  • LCD Touch Screen
  • 0.0550,000 cc/(m24h0.1MPa), 0.05500 g/(m24h)
  • Microcomputer Control
  • 0-80 mm
  • 100 mm
  • Bench-top
  • 450 mm
  • 10 seconds
  • 50 Hz
  • RS232/USB
  • 15C~55C (Adjustable)

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Advanced Sensor Technology

By integrating imported electrochemical and infrared sensors, this permeation testing system guarantees accurate and consistent measurements of oxygen and water vapor permeability. The sophisticated sensor array enables rapid response (within 10 seconds), high sensitivity, and reliable long-term operation, making it ideal for demanding quality assurance processes across multiple industries including packaging and pharmaceuticals.


Comprehensive Data Output and Management

The system supports both digital and printable report formats, simplifying documentation and audit trails. With proprietary PC connectivity software, users can store up to 2,000 test data sets, manage results efficiently, and perform multi-point calibration. Automated and manual calibration options ensure ongoing accuracy, while data can be exported via standard interfaces including RS232 and USB.


Flexible Testing Modes and Industrial Compliance

Offering both isostatic and dynamic test modes, the system easily adapts to various sample types and testing needs. It complies with global standards such as ASTM D3985, ASTM F1249, ISO 15106, and GB/T 19789, ensuring reliable results that are recognized internationally. Adjustable temperature and humidity ranges allow simulation of real-world conditions, enhancing relevance for R&D and production contexts.

FAQ's of Packaging Oxygen and Water Vapor Permeation Testing System for Diverse Industries:


Q: How does the oxygen and water vapor permeation testing system operate?

A: The testing system uses advanced electrochemical and infrared sensors to measure the transmission rates of oxygen and water vapor through packaging materials. Samples are placed in stainless steel chambers, where controlled test conditions (temperature and humidity) are applied. The system provides results digitally or in printable formats, and supports both automatic and manual calibration for precise measurements.

Q: What types of materials and industries can benefit from this system?

A: This equipment is designed for films, flexible packaging, pharmaceutical blister packs, food containers, electronics, and specialty materials. Its high accuracy and compliance with ASTM, ISO, and GB/T standards make it suitable for quality control, product development, and regulatory testing in a wide range of industries.

Q: What safety and durability features are incorporated in this system?

A: Safety features include overload protection and gas leak detection, ensuring secure operation at all times. The test chamber is made from stainless steel with an anti-corrosive coating for enhanced longevity. Additional safeguards such as automatic shutoff further contribute to reliability during laboratory and industrial testing.

Q: How is calibration managed, and how often should it be performed?

A: The system supports both automatic and manual calibration modes to maintain measurement accuracy. Multi-point calibration can be performed before test runs, with frequency depending on internal quality protocols or industry standards. Both methods are user-friendly and guided by intuitive LCD touch screen prompts.

Q: When is the data from a test available, and how is it stored or exported?

A: Test durations typically range from 3 to 24 hours, depending on the material and test parameters. Results are available promptly and can be viewed on the LCD touch screen, stored internally (up to 2,000 sets), or exported via RS232 or USB for further analysis and reporting.

Q: Where should the testing system be installed for optimal use?

A: The system is best installed in laboratory or industrial quality control environments, ideally in areas with regulated ambient conditions (temperature: 10C-40C, humidity 85% RH). Onsite installation and training services are available to assist with setup and user familiarization.

Q: What are the key benefits of using this permeation testing system?

A: Users benefit from high-precision, repeatable results; robust data management; compliance with international testing standards; and flexible testing for different materials. The system's automation, safety features, and extensive capacity for simultaneous tests streamline quality control, enhance product development, and support regulatory compliance efficiently.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.