Call Us
Send Inquiry
ASTM D1434 Battery Diaphragms Gas Permeability Tester

ASTM D1434 Battery Diaphragms Gas Permeability Tester

50000 USD ($)/Set

Product Details:

  • Measuring Range 0.011000 cc/m224h0.1MPa
  • Specimen Size 100 mm (standard)
  • Number of Specimens 1 or more (custom fixture)
  • Resolution 0.001 cc/m224h0.1MPa
  • Humidity 30%80% RH (adjustable)
  • Operating Voltage 220V AC, 50Hz
  • Frequency 50Hz
  • Click to View more
X

ASTM D1434 Battery Diaphragms Gas Permeability Tester Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set
  • 1 Set

ASTM D1434 Battery Diaphragms Gas Permeability Tester Product Specifications

  • Battery diaphragm, films, membranes gas permeability/airtightness measurement
  • Touch screen LCD display
  • 100 mm
  • Automatic data calculation and report creation, leakage alarm, multi-unit switching
  • 0.010.3 MPa (adjustable)
  • USB/RS232
  • 0.05 to 10 mm/min (adjustable)
  • Automatic
  • AC 220V 10%, 50Hz
  • Approx. 50 kg
  • 1% F.S.
  • Benchtop
  • 2 seconds
  • 15C50C (programmable)
  • 220V AC, 50Hz
  • 30%80% RH (adjustable)
  • Microprocessor controlled
  • 50 mm
  • 1 or more (custom fixture)
  • 0.001 cc/m224h0.1MPa
  • 0.011000 cc/m224h0.1MPa
  • 100 mm (standard)
  • Customizable as per request
  • 6 mm
  • 450 mm
  • Gas Permeability Tester
  • 0.011000 cc/m224h0.1MPa (customizable)
  • 50Hz
  • Laboratory, R&D, and quality control

Product Description

Product Features

  • Gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of the specimen could be obtained at one operation
  • 3 distinct or equivalent specimens could be tested individually with independent test results at one operation
  • Wide range and high precision temperature and humidity control to meet various test conditions
  • The instrument comes with two test modes: proportional mode and standard mode
  • Test range could be extended based on user requirements to test the materials with high permeability
  • Test results could be easily obtained even at extreme condition by data fitting function, which could work at any temperature
  • The instrument could be used to test poisonous, inflammable, and explosive gases (customization required)
  • The instrument is controlled by computer and test process is automatic
  • Reference film for fast calibration to ensure accurate and universal test data
  • Standard RS232 port for convenient data transfer
  • Supports LystemTM Lab Data Sharing System for uniform management of test results and test reports

Principle

The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between two chambers. The gas permeates through the specimen from the higher pressure side into the lower side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber

Standards

This test instrument conforms to the following standards:
ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003

Applications

This test instrument is applicable to the determination of gas permeability of:

Basic Applications
  • Films
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
  • Sheeting
    Including engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
Extended Applications
  • Various Gases
    Test the permeability of various types of gases, e.g. O2, CO2, N2, Air and He
  • Inflammable, Explosive Gases
    Test the permeability of inflammable and explosive gases
  • Biodegradable Films
    Test gas permeability of various sorts of biodegradable films, e.g. starch-based biodegradable bags
  • Materials for Aerospace Usage
    This instrument can test the Helium permeability of airship gas bags
  • Paper and Paper Board
    Test gas permeability of paper and paper-plastic composite materials, e.g. aluminized paper for cigarette packages, Tetra Pak sheeting, paper bowls for instant noodles and disposable paper cups
  • Paint Films
    Test gas permeability of substrates coated paint films
  • Glass Fiber Cloth and Paper
    Including glass fiber cloth and paper materials, e.g. Teflon paint cloth, Teflon welding cloth and Teflon silicon rubber cloth
  • Soft Tube Materials for Cosmetics
    Including various types of cosmetic tubes, aluminum-plastic tubes and toothpaste tubes
  • Rubber Sheeting
    Including various sorts of rubber sheeting, e.g. car tires

Technical Specifications

Specifications Film Test
Test Range 0.0550,000 cm3/m224h0.1MPa (standard volume)
At least 500,000 cm3/m224h0.1MPa (extended volume)
Number of Specimens 3 (with independent test results)
Vacuum Resolution 0.1 Pa
Vacuum Degree of Test Chamber <20 Pa
Temperature 5C 95C
Accuracy 0.1C (standard)
Humidity 0%RH, 5%RHi95%RH
(automatic humidification function under 1040 can be customized)
Accuracy 1%RH
Specimen Size I97 mm
Test Area 38.48 cm2
Test Gas O2, N2 and CO2 (outside of supply scope)
Test Pressure -0.1 MPa +0.1 MPa
Gas Supply Pressure 0.4 MPa 0.6 MPa
Port Size I6 mm PU Tubing
Instrument Dimension 760 mm (L) x 575 mm (W) x 450 mm (H)
Power Supply 220VAC 50Hz / 120VAC 60Hz
Net Weight 88 kg

Configurations

Standard Configurations
Instrument, Constant Temperature Control Device, Professional Software, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump(Imported)
Optional Parts
Blades for Sample Cutter, Vacuum Grease, Vacuum Pump Oil, Fast Quantitative Filter Paper
Note
1. The gas supply port of the instrument is I6 mm PU tubing;
2. Customers will need to prepare for gas supply and distilled water.


High-Precision and Versatile Testing

This tester supports a wide range of test conditions including customizable gas pressure, humidity, and temperature settings. Thanks to microprocessor control and a high-precision capacitance sensor, it ensures reliable, accurate results for even the most demanding laboratory, R&D, or production environments.


User-Friendly Operation and Data Management

Featuring a touchscreen LCD display and PC software support, users can perform quick data analysis, easy export, and store up to 1000 test records. Automated calculation, report creation, and a leakage alarm further streamline the testing process, improving laboratory efficiency and data traceability.


Durable Design for Long-Term Use

With a stainless steel test chamber and chemical-resistant silicone rubber seals, this instrument is designed for extended durability and resistance to harsh laboratory chemicals. The benchtop mounting and moderate weight (approx. 50 kg) allow flexible placement without occupying excessive laboratory space.

FAQ's of ASTM D1434 Battery Diaphragms Gas Permeability Tester:


Q: What types of samples are compatible with the ASTM D1434 Battery Diaphragms Gas Permeability Tester?

A: This equipment is suited for testing battery diaphragms, films, and membranes, with a standard specimen size of 100 mm. Custom fixtures allow testing of one or more specimens at a time, making it versatile for various laboratory and quality control applications.

Q: How does the tester ensure measurement accuracy and repeatability?

A: Accuracy is guaranteed by the high-precision capacitance pressure sensor and robust calibration options (both automatic and manual). The instrument achieves 1% F.S. accuracy and offers programmable test conditions to control variables such as temperature, humidity, and gas pressure.

Q: When is it recommended to use automatic versus manual calibration?

A: Automatic calibration is ideal for routine daily testing and minimizes operator intervention, while manual calibration can be used for specific research requirements or when unusual test conditions demand direct input from the user.

Q: Where does data from the tests get stored and how can it be accessed?

A: All test results are stored internally with capacity for up to 1000 records. Data can easily be exported or analyzed via the included PC software, using USB or RS232 communication interfaces, allowing seamless reporting and integration into laboratory information systems.

Q: What is the testing process like with this gas permeability tester?

A: Sample preparation is facilitated by the included tool. The specimen is mounted into the chamber (with adjustable sealing), conditions are set on the touchscreen, and the test is performed automatically. The system calculates and displays results instantly, with a leakage alarm to alert for any test anomalies.

Q: What key benefits does this tester offer to laboratory and quality control teams?

A: Key benefits include automated reporting, reliable accuracy and repeatability, flexible test condition programming, and strong chemical resistance. These features accelerate testing, improve data reliability, and ensure the tester withstands demanding laboratory usage.

Q: How does the machine accommodate varying laboratory setups or requirements?

A: The tester supports customizable capacity, adjustable port sizes, and programmable test conditions. Its benchtop design, moderate weight, and robust safety features make it suitable for most laboratory configurations, whether for R&D, quality control, or manufacturing verification.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.