Product Description
Product FeaturesNote1
Professional Test Modes to Meet Various Testing Demands
- Multiple independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, and compression test, etc. at users choice
- The instrument supports bidirectional testing modes and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, which ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, which avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- Large size touch screen tablet for better viewing and easy operation
- Brand new software and system provide smooth and simplified operating experience
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610H is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical SpecificationsNote2
| Specifications |
C610H Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) |
| Accuracy |
0.5% of indicated value (2%FS100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0.05 500 mm/min |
| Speed Accuracy |
0.5% of indicated value (1%100% of maximum speed) |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (72.5psii101.5psi) |
| Stroke |
1000 mm |
| Instrument Dimension |
500 mm (L) 520 mm (W) 1900 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
110 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, Tablet, Pneumatic Sample Grips
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Precision Adhesion Testing for Li-Ion ElectrodesThis equipment is engineered for accurate collector-active material adhesion measurement in lithium-ion battery electrodes. By offering both 90 and 180 peel test options and a wide measuring range up to 1000 N, it provides robust, reproducible data essential for R&D and quality control processes. Custom fixtures ensure tight sample security, while compliance with international standards (ISO/IEC/GB) guarantees trustworthy outputs.
User-Friendly Operation and Multilingual SupportThe system features a password-protected digital LCD that supports multiple languages, simplifying operation for global users. Data acquisition is seamless with automatic recording and exportable CSV/PDF results. Its intuitive interface and adjustable test controls allow easy adaptation for various research scenarios, enhancing productivity and data integrity.
Reliable and Compliant Laboratory SolutionSupplied with its calibration certificate, the adhesion tester operates under controlled, vibration- and dust-free indoor environments. Versatile test speeds, high sensor accuracy (0.5% F.S.), and wide parameter customization make it ideal for both routine laboratory assessments and advanced material studies.
FAQ's of Assessing Collector-Active Material Adhesion in Li-Ion Electrodes:
Q: How is adhesion strength assessed with this system in Li-ion battery electrodes?
A: Adhesion strength is measured using either a 90 or 180 peel test, where the electrode specimen is pulled at a controlled angle and speed. The high-precision load cell quantifies the force required to separate the collector from the active material, reporting adhesion values in N/cm or N/mm.
Q: What data export formats are available for test results?
A: Test results, including the adhesion force graph and numerical data, can be exported in CSV or PDF formats through the system's USB or RS232 interfaces, facilitating easy sharing and documentation.
Q: When should calibration and maintenance be performed on the device?
A: Calibration is conducted prior to delivery and documented with a certificate. It is recommended to check calibration annually or after extensive use, particularly if you observe inconsistencies in readings.
Q: Where should the Adhesion Test System be operated for optimal results?
A: Operate the system in an indoor, vibration-free, and dust-free environment. The recommended ambient conditions are 20-80% relative humidity and a temperature range of 15-35C to maintain precision and reliability.
Q: What is the process for conducting an adhesion test with this equipment?
A: Install the electrode on the customizable fixture, set the desired peel angle (90/180), adjust speed and test parameters, and select control mode (automatic/manual). Initiate the test; data is automatically recorded and displayed, with analysis and export features available post-test.
Q: How does password protection enhance the system's usage in laboratories?
A: Password protection restricts unauthorized access, ensuring that only trained personnel can operate the equipment or retrieve sensitive test data, thereby maintaining data security and compliance with laboratory protocols.
Q: What are the user benefits of utilizing this adhesion testing system?
A: Users benefit from highly accurate, standard-compliant measurements, versatile fixture and clamp system, easy data management, rapid test setup, multilingual support, and comprehensive test parameter customization, all contributing to improved efficiency and reliable research outcomes.