Call Us
Send Inquiry Send SMS
Labthink Permeation Testing Solution for Breathability Testing of Organosilicon Coatings

Labthink Permeation Testing Solution for Breathability Testing of Organosilicon Coatings

50000 USD ($)/Set

Product Details:

  • Frequency 50 Hz
  • Power Supply AC 220V, 50Hz
  • Display Type LCD touch screen
  • Port Size 6 mm gas inlet
  • Equipment Type Automated Permeation Testing System
  • Response Time <5 seconds
  • Hardness Industrial-grade, corrosion-resistant
  • Click to View more
X

Labthink Permeation Testing Solution for Breathability Testing of Organosilicon Coatings Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Labthink Permeation Testing Solution for Breathability Testing of Organosilicon Coatings Product Specifications

  • RS232/USB
  • 0.6 MPa (max)
  • Microprocessor-based
  • Automated data acquisition, rapid temperature and humidity control, multi-parameter setting
  • 100 mm
  • Fully automatic
  • 0.01~1,000 ml/m2d
  • 420 mm
  • Up to 95% RH (programmable)
  • 0.001 ml/m2d
  • 0.01 ml/m2d
  • 3
  • 50 Hz
  • AC 220V, 50Hz
  • Automated Permeation Testing System
  • 0.01~10 ml/m2d
  • <5 seconds
  • LCD touch screen
  • 6 mm gas inlet
  • Laboratory breathability testing for coatings
  • 220V AC
  • Industrial-grade, corrosion-resistant
  • Three simultaneous tests
  • Bench-top
  • 0.0110,000 ml/m2d
  • 74 mm diameter
  • Breathability and permeation testing of organosilicon coatings
  • 15C~50C (0.1C)
  • 45 kg
  • Adjustable, up to 200 mm

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Advanced Environmental Control for Reliable Results

The system incorporates built-in PID controllers for temperature and humidity, ensuring optimal and stable test environments between 15C and 50C, up to 95% relative humidity. Precision is reinforced with 0.1C temperature accuracy, making it ideal for testing the nuanced breathability of organosilicon coatings under various laboratory conditions.


Fully Automated, User-Friendly Operation

With its microprocessor-based control and LCD touch screen, the Labthink solution offers streamlined, fully automatic testing processes. Automated data acquisition, quick calibration, rapid environmental adjustments, and multi-parameter settings minimize operator intervention, saving both time and effort during routine breathability assessments.


Comprehensive Compliance and Versatile Applications

Certified with ISO 15106, ASTM D3985, and ASTM F1249 standards, the system ensures data reliability and compatibility with international testing requirements. It can simultaneously test up to three specimens, making it suitable for material R&D, quality control, and regulatory compliance across research and manufacturing sectors focused on organosilicon coatings.

FAQ's of Labthink Permeation Testing Solution for Breathability Testing of Organosilicon Coatings:


Q: How does the Labthink Permeation Testing Solution ensure accurate breathability testing of organosilicon coatings?

A: The instrument uses a stainless steel testing chamber with built-in PID temperature and humidity controls, providing highly stable test conditions. Automatic calibration with certified standard films also contributes to accuracy, along with a high-resolution sensor (0.001 ml/m2d) and a prompt response time of under 5 seconds.

Q: What gases are compatible with this permeation testing system?

A: The system is designed to be compatible with oxygen, nitrogen, carbon dioxide, and air, allowing for versatile breathability and permeation testing of coatings under different atmospheric conditions.

Q: When can users access stored test results and how much data can be stored?

A: The onboard memory of the system allows users to store up to 10,000 test results, which can be accessed at any time via the LCD touchscreen interface. Data can also be exported through the available RS232 or USB ports for further analysis or record-keeping.

Q: Where is the best environment to operate this permeation testing equipment?

A: For optimal performance, the equipment should be used in laboratory settings with temperatures between 15C and 60C and relative humidity below 80% (non-condensing). The bench-top configuration makes it suitable for standard laboratory workstations.

Q: What is the process for conducting a breathability test with this system?

A: Users install up to three specimens (74 mm diameter each), set test parameters on the touch screen, and select continuous or discrete test mode. After automatic calibration, environmental conditions are programmed, and the test runs automatically, collecting and storing data throughout the duration.

Q: How does the system support different user preferences and safety requirements?

A: The interface supports both English and Chinese, making it accessible to a wider range of users. Safety features include automatic shutdown on sensor error or overpressure, ensuring equipment integrity and operator safety.

Q: What are the key benefits of using the Labthink solution for breathability testing?

A: The system provides rapid, precise results with minimal operator involvement, supports multi-specimen testing, ensures compliance with major standards, and offers extensive data management-all wrapped in a durable, corrosion-resistant, and easy-to-operate package.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.