Product Description
High Precision
- Patented integrated test block with advanced hydrodynamic and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test block is precisely temperature controlled and remains stable throughout the test.
- Temperature and humidity sensor for independent monitoring of test cells.
High Efficiency
- Three identical specimens can be tested simultaneously, which meets the requirements for parallel test.
- Three distinct specimens can be tested under the same testing condition, delivering higher throughput while reducing the number of instruments required.
Labor Saving
- Automatic temperature and humidity control eliminates the need for operator monitoring and adjustment.
- Automatic flow rate control ensures constant flow during the testing process and minimizes any errors caused by an unstable flow rate.
- No need to verify the system using different reference film for different testing range.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Integrated Testing Block
The patented three-cell integrated test block structure using advanced thermodynamics and hydrodynamics analysis greatly improves the temperature, humidity and flow measurement accuracy across the three test cells and supports simultaneous testing of three samples.
Automatic Control of Temperature, Humidity and Flow Rate
The internal temperature and humidity of the instrument are automatically adjusted with temperature and humidity sensors, maintaining the stability of the test specimen environment.
Automatic flow rate control ensures the constant flow during the testing process and minimizes any errors caused by an unstable flow rate.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system, meets the requirements for centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Test Principle
The pre-conditioned specimen is mounted between the upper and lower chambers at ambient atmospheric pressure. The upper chamber contains oxygen or air and the lower chamber is slowly purged by a stream of nitrogen. Due to the concentration difference between the two chambers, oxygen molecules permeate through the specimen into the nitrogen side and are taken to the coulometric sensor where proportional electrical signals are generated. The oxygen transmission rate is then obtained by analyzing the signals and calculating the volume of oxygen measured by the sensor. For whole package samples, high purity nitrogen flows inside the package, and oxygen or air flows outside.
Test Standards
ASTM D3985, ASTM F1307, ASTM F1927 (option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B and YBB 00082003-2015
Applications
| Basic Applications |
- Films
Plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
|
- Sheeting
PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheeting materials
|
- Packages
Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups
|
| Extended Applications |
- Closure Systems
Oxygen barrier property of various closure systems for bottles cartons and pouches.
|
- Solar Back-Sheets
Oxygen permeability test of solar back-sheets
|
- Plastic Tubes
Oxygen permeability test of various sorts of tubes, e.g cosmetic tubes.
|
- Blister Packs
Test oxygen transmission rate of the whole blister packs
|
- Automotive and Small Engine Fuel Tanks
Permeability of plastic fuel tanks.
|
- Battery Plastic Shell
Oxygen transmission rate of battery plastic shell
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C230H |
| Test Range |
cm3/(m2d) (Standard) |
0.01 200 |
| cc/(100in2day) |
0.0007 12.9 |
| cm3/(pkgd)(Package) |
0.00005 1 |
| Resolution |
cm3/(m2day) |
0.001 |
| Repeatability |
cm3/(m2day) |
0.01 or 2% |
| Test Temperature |
C |
10 55 0.2 |
| Test Humidity |
RH |
O2: 0%, 5% 901%, 100% Carrier Gas: 0%, 5% 902%(optional) |
| Additional Functions |
Package Test (3L Max.) |
Optional |
| DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 test chambers |
| Specimen Size |
108 mm X 108 mm |
| Specimen Thickness |
3 mm |
| Standard Test Area |
50 cm2 |
| Carrier Gas |
99.999% High-purity Nitrogen (outside of supply scope) |
| Carrier Gas Pressure |
0.28 MPa/40.6psi |
| Port Size |
1/8 inch metal tubing |
Accurate and Reliable Oxygen Permeability TestingEngineered for excellence, this tester provides highly accurate measurement of oxygen transmission rates in packaging materials, with test ranges spanning 0.01 to 65,000 cm3/(m224h0.1MPa) and resolution as fine as 0.001 cm3/(m224h0.1MPa). Temperature, humidity, and speed are all adjustable, ensuring adaptability to various testing protocols and specimen conditions.
Automated, User-Friendly OperationFeaturing fully automatic operation controlled via a microcomputer and intuitive touch screen, the instrument allows for seamless test setup and execution. Parameters such as test stroke, humidity, and chamber temperature can be precisely configured. The high-capacity measurement chamber supports quick cycle speeds (1-10 cycles/min) for efficient throughput.
Compliant with International Standards and Industry RequirementsThis instrument is compliant with major international oxygen transmission rate testing standards, making it ideal for exporters, manufacturers, and suppliers globally. On-site installation and bilingual (English/Chinese) user guidance ensure swift integration and operator proficiency. Data storage, export, and printing capabilities allow for comprehensive documentation and analysis of results.
FAQ's of Pouches Package Oxygen Transmission Rate Tester:
Q: How does the Pouches Package Oxygen Transmission Rate Tester work?
A: This oxygen transmission rate tester operates using the Coulometric Sensor Method, following standards such as ASTM D3985, ISO 15105-2, and JIS K7126-B. It detects the amount of oxygen passing through packaging material, providing accurate measurements using adjustable environmental controls.
Q: What types of packaging can be tested with this equipment?
A: The device is designed for testing pouches and flexible packaging, making it suitable for materials requiring evaluation of their oxygen barrier properties. It can accommodate sample sizes up to 97 mm x 97 mm and supports up to three independent specimens simultaneously.
Q: When should oxygen transmission rate testing be performed on packaging materials?
A: Testing is essential during material development, quality control, and before launching new packaging to ensure optimal product protection. It helps manufacturers assess if their packaging meets regulatory and performance standards regarding oxygen permeability.
Q: Where is this oxygen transmission rate tester commonly used?
A: This instrument is primarily used in laboratory environments within packaging manufacturing companies, research institutions, and quality assurance departments concerned with packaging integrity and shelf-life performance.
Q: What is the process for conducting a test with this instrument?
A: To perform a test, load your specimen into the high-capacity stainless steel chamber, set the required parameters (temperature, humidity, test speed), and initiate the cycle via the touch screen. The system will automatically control and monitor the test, storing or printing the results according to your data output selection.
Q: How does this tester benefit packaging manufacturers and exporters?
A: The tester provides precise data on oxygen permeability, allowing manufacturers to verify and optimize their packaging materials for extended product shelf life. It also assists exporters in meeting international compliance requirements, thereby strengthening supply chain reliability.
Q: Can the tester's data be integrated with other laboratory systems?
A: Yes, data can be exported through USB and RS232 interfaces or printed directly. This enables seamless integration with laboratory information management systems, facilitating comprehensive record-keeping and reporting.