Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 12 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360H |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
12 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/ni141-12i14g/(m2day) |
| 645/ni141-12i14g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
12 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
I74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
I6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Precision and Compliance for Medical TestingBuilt to meet ASTM E96 and ISO 2528 standards, this WVTR Testing Machine ensures trustworthy results for critical applications, especially in the medical and pharmaceutical industries. Its reliable measurement range and high accuracy make it essential for testing hydrogel dressings and other moisture-sensitive materials in research, development, and quality assurance environments.
User-Friendly Operation and High ThroughputWith a semi-automatic benchtop design, touchscreen LCD, and graphical data analysis, operation is straightforward and efficient. This instrument supports testing up to three specimens simultaneously, featuring quick response times, automated data logging, and extensive storage for 50,000 test records. Its high throughput capacity suits fast-paced laboratory settings without compromising result integrity.
Advanced Data Management and ConnectivityThe integrated software enables comprehensive data management, and robust export options allow users to generate CSV or PDF reports for easy sharing. Multiple interface options (USB & RS232) simplify connectivity to lab networks or external devices, streamlining workflows and supporting detailed compliance reporting and audit trails.
FAQ's of Selecting the Right WVTR Testing Equipment for Medical Hydrogel Dressings:
Q: How does the factory and field calibration support benefit WVTR testing for medical hydrogel dressings?
A: Factory and field calibration ensures that the WVTR Testing Machine consistently delivers accurate and reliable results in both laboratory and field environments. This flexibility is especially important for medical and pharmaceutical applications, maintaining measurement integrity throughout the equipment's lifecycle.
Q: What compliance standards does this WVTR Testing Machine meet, and why is that important?
A: The instrument complies with ASTM E96 and ISO 2528 standards, which are internationally recognized benchmarks for WVTR measurements. Adherence to these standards guarantees that test results are credible and reproducible, supporting regulatory submissions and quality assurance processes.
Q: When should I export data from the WVTR Testing Machine, and what formats are available?
A: Data should be exported after each test or batch of analyses, particularly for documentation or reporting purposes. The machine allows users to export data in CSV and PDF formats, making it compatible with most laboratory information systems and facilitating traceability.
Q: Where can this WVTR Testing Machine be installed, and what are the mounting options?
A: Designed as a benchtop instrument, this testing machine is suitable for installation in medical, pharmaceutical, and research laboratories. Its compact industrial-grade construction fits easily on standard laboratory benches and dedicated workspace areas.
Q: What is the process for testing hydrogel dressings using this equipment?
A: Place specimens (up to three simultaneously) in the specimen clamps and sealing rings provided. Set the test parameters via the microprocessor-controlled touchscreen, and initiate the run. The system measures water vapor transmission, automatically logs data, and provides graphical and numerical results for export.
Q: How can users benefit from the machine's data storage and management capabilities?
A: With a 50,000-test memory, automatic logging, and quick data access, users can efficiently manage and review extensive test histories. This aids trend analysis, audit readiness, and compliance with regulatory requirements. The included software and export options further enhance these data management advantages.
Q: What safety features are integrated into the WVTR Testing Machine during operation?
A: The machine includes overheat and overpressure protection mechanisms. These features not only safeguard users and samples but also protect the equipment itself, ensuring consistent performance and minimizing downtime due to unexpected incidents.