Product Description
Product FeaturesNote1
- The new ceramic oxygen sensor developed by Labthink has the characteristics of high precision and good repeatability.
- Ceramic oxygen sensor is non consumption type and has long service life.
- PC material operation panel, menu interface, LCD display, easy to operate and view the results.
- The system supports Chinese and English bilingual operating environment to meet the needs of different language users.
- The microcomputer control system can analyze and process the test data and output the report.
- It is easy to print the test results at any time with the embedded micro printer.
- The system has built-in data storage to meet the needs of large amount of data storage.
- Portable, easy to use in laboratory or production sites.
- Equipped with RS232 interface and professional software, which convenient for computer connection and data import and export.
Test Principle
The gas in the sample is pumped into the sensor through the vacuum pump, and the sensor outputs the real time current and voltage signals of O2 and CO2 (optional) concentration of the gas in the sample. The instrument calculates the content of O2 and CO2 (optional) in the gas by obtaining the current and voltage signal output by the sensor. After reaching the requirements for ending the tests, the tests stop, and the instrument records the concentration of O2 and CO2 (optional) in the gas tested in the sample.
Test Applications
| Basic Applications |
- Pouches/bags
It is suitable for the determination of O2 and CO2 (optional) content in non negative pressure pouches, packaging bags of coffee, cheese, milk tea, milk powder, bread, soybean powder, modified atmosphere packaging, ready to eat food, medicine and other non negative pressure packaging bags.
|
- Packaging Containers
It is suitable for the determination of O2 and CO2 (optional) in canned coffee, canned milk powder, canned food, cheese, canned, Tetra Pak, beverage and other packaging containers
|
| Extended Applications |
- Ampoule Bottles
It is suitable for testing the concentration of O2 and CO2 (optional) in the head gas of ampoules
|
Technical SpecificationsNote2
| Items |
Parameters |
| Type of Gas Measured |
O2 (Standard) |
CO2 (optional) |
| Measuring Range |
0.2%i21% |
2%i100% |
| Measurement Accuracy |
0.2% |
2% |
| Sample Size |
5ml (standard atmospheric pressure) |
20ml (standard atmospheric pressure) |
| Dimensions |
350mm (L) 330mm(W) 200mm(H) |
| Power Supply |
220VAC 50Hz / 120VAC 60Hz |
| Net Weight |
5.5 kg |
Product Configuration Note 1
| Standard Configuration |
Mainframe, micro printer, sampling needle, filter and gasket |
| Options |
CO2 sensor, professional software, communication cable, hard packaging sampler, underwater sampling device |
Note 1: The product functions, reference standards and configuration information are subject to the specific notes in the "Technical Parameters".
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Advanced Sensing for Reliable Packaging AnalysisOur analyzer integrates electrochemical and infrared sensors to deliver accurate gas detection. This dual-sensor approach ensures high sensitivity and robust performance, suitable for food and pharmaceutical packaging quality control. With customizable testing parameters and touch controls, users gain flexibility and efficiency across a range of applications.
Comprehensive Digital Output and MemoryAll measured gas data is displayed in high-resolution on a digital LCD screen and can be output via RS232 or USB for detailed, printable reports. With internal memory supporting up to 5,000 records, users can efficiently manage quality control documentation and trace results over time.
Flexible Sampling and Automated CalibrationNeedle/probe entry sampling allows the analyzer to accommodate different package types. Automatic and manual calibration options ensure ongoing measurement accuracy. The device is designed to alert operators to gas levels exceeding limits or system faults, reinforcing safety and reliability in every test.
FAQ's of Headspace gas analysis for Optimal Food and Medicine Packaging:
Q: How does the Headspace Gas Analyzer measure gas levels in packaging?
A: The analyzer uses advanced electrochemical and infrared sensors to detect and quantify oxygen, carbon dioxide, and nitrogen concentrations inside sealed packages. Sampling is achieved through a needle or probe entry, ensuring a precise and non-destructive measurement.
Q: What types of reports can be generated from test results?
A: Test results are digitally recorded and can be accessed via the instrument's LCD display. Reports are available in both digital and printable formats, supporting thorough documentation for quality control purposes.
Q: When should calibration be performed on this device?
A: The gas analyzer allows for both automatic and manual calibration. Routine calibration is recommended during regular maintenance or when test accuracy needs to be verified, ensuring precise measurements are maintained over time.
Q: Where can this analyzer be effectively used?
A: This device is ideal for use in food, pharmaceutical, and medicine packaging industries where monitoring internal gas composition is critical for product longevity and safety. Its portable bench-top design makes it suitable for laboratories and production environments.
Q: What is the process for conducting a sample test?
A: A single specimen, at least 20mm x 20mm in size, is placed in the testing area. Gas sampling is done using the needle/probe entry, and test parameters can be customized as needed. The analyzer processes readings rapidly, delivering results on its digital display in under 10 seconds.
Q: What benefits does this analyzer offer for quality assurance?
A: The equipment ensures that oxygen, carbon dioxide, and nitrogen levels in packaging meet industry standards. Quick response, high accuracy, and comprehensive reporting streamline quality checks, decrease product spoilage, and support regulatory compliance.