Call Us
Send Inquiry Send SMS
Packaging Tests in Edible Oil Safety - Oxygen Transmission Rate (OTR) Test

Packaging Tests in Edible Oil Safety - Oxygen Transmission Rate (OTR) Test

50000 USD ($)/Set

Product Details:

  • Operating Voltage 220 V
  • Measuring Range 0.01 ~ 10,000 ml/m2/day
  • Temperature 15C ~ 55C
  • Gas Pressure 0.6 MPa
  • Number of Specimens 1 - 3 (Simultaneous)
  • Interface Type RS232 / USB
  • Display Type LCD Touchscreen
  • Click to View more
X

Packaging Tests in Edible Oil Safety - Oxygen Transmission Rate (OTR) Test Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set
  • 1 Set

Packaging Tests in Edible Oil Safety - Oxygen Transmission Rate (OTR) Test Product Specifications

  • Approx. 45 kg
  • 0.6 MPa
  • 220 V
  • Testing oxygen transmission in packaging for edible oils
  • 15C ~ 55C
  • 0.01 ~ 10,000 ml/m2/day
  • Test up to 3 samples at once
  • RS232 / USB
  • 1 - 3 (Simultaneous)
  • Packaging material barrier property testing for edible oil safety
  • Micro-Computer Controlled
  • LCD Touchscreen
  • Better than 2% F.S.
  • 108 mm diameter
  • 0 ~ 100% RH (Controllable)
  • 50 mm
  • Bench-top
  • 3 seconds
  • 0 ~ 100 mm
  • No restriction (open design for specimen holder)
  • 0.01 ml/m2/day
  • Automatic
  • High accuracy sensor, automatic temperature and humidity control, user-friendly software
  • 0.01 ~ 10 ml/m2/day
  • 6 mm
  • 50 Hz
  • 0.01 ~ 10,000 ml/m2/day
  • Oxygen Transmission Rate Test Equipment
  • 220V, 50Hz

Product Description

Product FeaturesNote1

Coulometric Oxygen Sensor

  • The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
  • Designed according to ASTM D3985 with absolute value and no need to calibrate.
  • Super long service life, three times longer than traditional Coulometric oxygen sensor.
  • Functions of over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
  • In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

Effective Three-Cell

  • Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
  • Three samples are tested at the same time under the same condition, and the data are independent.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
  • Safe Performance: the instrument uses global famous brand with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
  • Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
  • Ultra wide test range, meet the barrier test (customized) of various materials.
  • Ultra wide temperature range, meet the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).

Testing Principle

The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.

Reference Standards

ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

Test Applications

Applications
  • Films
    The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
  • Sheet
    The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Parameters

Table 1: Test Parameters Note2

Parameters/Model C203H
Test Scope cc/(m2day) (standard area 50cm2) 0.01i200
0.005i200 (optional)
cc/(m2day) (standard area 50cm2) 0.01i400000i14Customizei14
cc/(m2day) (MASK area 5cm2) 0.12000 (optional)
cc/(m2day) (MASK area 1cm2) 0.510000 (optional)
Resolving Power cc/(m2day) 0.0001
Repeatability cc/(m2day) 0.01 or1%, whichever is greater
Temperature Range  15i50
560 (customized)
Temperature Fluctuation 0.05
Humidity Range %Rh (within standard temperature range) O2: 0%i145i901%
Carrier Gas: 0%, 5i902%
Extended Functions GP-01 Gas Purification Unit Optional
DataShieldTM Data Shield Note 3 Optional
GMP Computer System Requirements Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 sets
Sample Size 4.4 x 4.4i1411.2cm11.2cmi14
Sample Thickness 120 Mili143mmi14
Standard Test Area 50cm2
Gas Specification 99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer)
Air Source Pressure 40.6 PSI / 280 kPa
Interface Size 1 / 8 "metal tube
Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Power Supply 120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two)
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs(100kg)

Table 3: Product Configuration

Standard Configuration Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm
Options Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements
DataShieldTM Data ShieldNote3
Remarks The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.



Advanced OTR Testing for Edible Oil Packaging

Our state-of-the-art OTR test equipment offers reliable evaluation of oxygen barrier properties in packaging materials, vital for maintaining edible oil freshness and safety. The device's high-accuracy coulometric sensor method, combined with precise temperature and humidity controls, ensures repeatable and dependable results. This instrument supports testing up to three specimens at once, significantly enhancing laboratory productivity.


Versatile Data Management and User Experience

Export your test results seamlessly in CSV or PDF formats via RS232 or USB interfaces. The intuitive LCD touchscreen enables easy operation, while language support extends usability across global teams. Users benefit from automatic controls and a bench-top design, optimizing workflow in quality assurance environments.

FAQ's of Packaging Tests in Edible Oil Safety - Oxygen Transmission Rate (OTR) Test:


Q: How does the OTR tester assess oxygen transmission in edible oil packaging?

A: The Oxygen Transmission Rate tester employs the Coulometric sensor method according to ASTM D3985 and ISO 15105-2 standards. By exposing packaging samples to ambient air or pure oxygen, it measures the rate at which oxygen permeates through the material, providing accurate data to ensure the packaging's protective qualities for edible oils.

Q: What is the testing process for evaluating packaging materials?

A: Start by preparing up to three specimens with a 108 mm diameter. These are loaded into the high-grade stainless steel chamber. The system automatically controls temperature (15C to 55C) and humidity (0-100% RH) before exposing the sample to the selected test gas. Results are collected using a NIST traceable gas flow meter and analyzed by the micro-computer controller for precision.

Q: When should I conduct OTR tests on edible oil packaging?

A: OTR tests should be performed during material development, before commercial production, and for ongoing quality assurance. Regular testing ensures packaging maintains optimal oxygen barrier properties to protect the oil's flavor and shelf life.

Q: Where can the OTR testing equipment be used?

A: This bench-top device is suitable for quality control labs, packaging development departments, and manufacturing facilities. Its open design allows testing of various sample heights, making it versatile for different packaging formats used in the edible oil industry.

Q: What are the advantages of using this OTR tester for edible oil safety?

A: Benefits include high accuracy (better than 2% F.S.), rapid results (3 seconds response), simultaneous testing of up to three samples, and automatic conditions control. Data can be easily exported, and multiple language options widen usability. This ensures efficient, reliable assessment of your packaging's oxygen barrier properties.

Q: How is data managed and output from the device?

A: Test results are viewable on the integrated LCD touchscreen and can be exported in CSV or PDF formats through RS232 or USB interfaces. This ensures easy integration with laboratory information management systems and straightforward record keeping.

Q: What is the usage benefit for packaging manufacturers and suppliers?

A: By verifying and optimizing the oxygen barrier properties of packaging materials, manufacturers and suppliers can ensure product quality, extend edible oil shelf life, and meet regulatory requirements. The automatic operation and high throughput capacity increase laboratory efficiency and reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.