Product Details:

  • Features Multi-layer film compatibility; Microcomputer control; Real-time data display
  • Resolution 0.01 cc
  • Gas Pressure 0.30.6 MPa
  • Application Testing gas barrier property of multi-layer composite films
  • Operating Voltage 220 V AC
  • Test Range 0.0510,000 cc/m24h
  • Response Time 2 seconds
  • Click to View more
X

Multi-Layer Complex Films Gas Barrier Performance Testing Instrument Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Multi-Layer Complex Films Gas Barrier Performance Testing Instrument Product Specifications

  • Touch Panel/Automatic
  • 20%90% RH (controllable)
  • Barrier property analysis for industrial packaging films
  • 7 inch Touch Screen LCD
  • Gas Barrier Performance Testing Instrument
  • 13 (customizable chamber)
  • 50 Hz
  • Approximately 85 kg
  • AC 220V, 50Hz
  • 0.0510,000 cc/m24h
  • 1050 (programmable)
  • Standard 6 mm gas port
  • 0.01 cc
  • 0.30.6 MPa
  • 0200 mm
  • up to 350 mm
  • Multi-layer film compatibility; Microcomputer control; Real-time data display
  • 0.0510,000 cc/m24h
  • 100 mm 100 mm (standard)
  • 2 seconds
  • Testing gas barrier property of multi-layer composite films
  • Laboratory scale
  • 220 V AC
  • Benchtop
  • Automatic
  • 0.110 mm/min adjustable
  • 0.01 cc/m24h
  • 600 mm
  • RS232/USB

Product Description

Product Features

  • Gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of the specimen could be obtained at one operation
  • 3 distinct or equivalent specimens could be tested individually with independent test results at one operation
  • Wide range and high precision temperature and humidity control to meet various test conditions
  • The instrument comes with two test modes: proportional mode and standard mode
  • Test range could be extended based on user requirements to test the materials with high permeability
  • Test results could be easily obtained even at extreme condition by data fitting function, which could work at any temperature
  • The instrument could be used to test poisonous, inflammable, and explosive gases (customization required)
  • The instrument is controlled by computer and test process is automatic
  • Reference film for fast calibration to ensure accurate and universal test data
  • Standard RS232 port for convenient data transfer
  • Supports LystemTM Lab Data Sharing System for uniform management of test results and test reports

Principle

The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between two chambers. The gas permeates through the specimen from the higher pressure side into the lower side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber

Standards

This test instrument conforms to the following standards:
ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003

Applications

This test instrument is applicable to the determination of gas permeability of:

Basic Applications
  • Films
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
  • Sheeting
    Including engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
Extended Applications
  • Various Gases
    Test the permeability of various types of gases, e.g. O2, CO2, N2, Air and He
  • Inflammable, Explosive Gases
    Test the permeability of inflammable and explosive gases
  • Biodegradable Films
    Test gas permeability of various sorts of biodegradable films, e.g. starch-based biodegradable bags
  • Materials for Aerospace Usage
    This instrument can test the Helium permeability of airship gas bags
  • Paper and Paper Board
    Test gas permeability of paper and paper-plastic composite materials, e.g. aluminized paper for cigarette packages, Tetra Pak sheeting, paper bowls for instant noodles and disposable paper cups
  • Paint Films
    Test gas permeability of substrates coated paint films
  • Glass Fiber Cloth and Paper
    Including glass fiber cloth and paper materials, e.g. Teflon paint cloth, Teflon welding cloth and Teflon silicon rubber cloth
  • Soft Tube Materials for Cosmetics
    Including various types of cosmetic tubes, aluminum-plastic tubes and toothpaste tubes
  • Rubber Sheeting
    Including various sorts of rubber sheeting, e.g. car tires

Technical Specifications

Specifications Film Test
Test Range 0.0550,000 cm3/m224h0.1MPa (standard volume)
At least 500,000 cm3/m224h0.1MPa (extended volume)
Number of Specimens 3 (with independent test results)
Vacuum Resolution 0.1 Pa
Vacuum Degree of Test Chamber <20 Pa
Temperature 5C 95C
Accuracy 0.1C (standard)
Humidity 0%RH, 5%RHi95%RH
(automatic humidification function under 1040 can be customized)
Accuracy 1%RH
Specimen Size I97 mm
Test Area 38.48 cm2
Test Gas O2, N2 and CO2 (outside of supply scope)
Test Pressure -0.1 MPa +0.1 MPa
Gas Supply Pressure 0.4 MPa 0.6 MPa
Port Size I6 mm PU Tubing
Instrument Dimension 760 mm (L) x 575 mm (W) x 450 mm (H)
Power Supply 220VAC 50Hz / 120VAC 60Hz
Net Weight 88 kg

Configurations

Standard Configurations
Instrument, Constant Temperature Control Device, Professional Software, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump(Imported)
Optional Parts
Blades for Sample Cutter, Vacuum Grease, Vacuum Pump Oil, Fast Quantitative Filter Paper
Note
1. The gas supply port of the instrument is I6 mm PU tubing;
2. Customers will need to prepare for gas supply and distilled water.


Versatile Gas Permeability Assessment

This instrument offers comprehensive testing for O2, CO2, N2, and additional user-selected gases, accommodating a diverse array of multi-layer packaging films. Its independent test chamber, customizable for up to three specimens, ensures uniformity and reliable data across multiple sample types. Automatic controls and real-time display further enhance operational flexibility in the laboratory.


Precision and Efficiency in Every Test

With a measuring range of 0.05-10,000 cc/m224h and accuracy of 0.01 cc/m224h, the instrument delivers highly dependable results swiftly, with response times as quick as two seconds. The adjustable test speed and programmable environmental conditions allow tailored testing to industry protocols, making it a valuable asset for quality control and research.


Robust Design for Laboratory Use

Built from spray-coated cold-rolled steel, this benchtop instrument boasts durability and easy maintenance. Its sealed chamber and included film cutting template streamline sample setup, while automatic calibration and over-pressure alarms ensure safety and accuracy. Data can be stored locally or exported via USB, offering flexible integration into laboratory workflow.

FAQ's of Multi-Layer Complex Films Gas Barrier Performance Testing Instrument:


Q: How does the instrument measure the gas barrier properties of multi-layer films?

A: The instrument employs coulometric and manometric methods to accurately detect and quantify the permeability of gases such as O2, CO2, and N2 through the film sample. It automatically monitors and records data under programmable temperature and humidity conditions according to ASTM D3985 and ISO 15105-2 standards.

Q: What types of gases can be tested using this equipment?

A: Standard configurations allow for the testing of oxygen, carbon dioxide, and nitrogen permeability. The system's design also accommodates custom gas selections to meet unique testing requirements.

Q: When should I use the automatic versus manual calibration function?

A: Automatic calibration is suitable for routine operation and maintaining consistent accuracy. Manual calibration is recommended when integrating new test protocols or after significant maintenance, ensuring the system's precise alignment with your standards.

Q: Where is this instrument typically utilized?

A: This gas barrier performance tester is primarily used in laboratory settings of manufacturers, exporters, and suppliers in the packaging industry, especially for evaluating the barrier properties of industrial multi-layer composite films.

Q: What is the process for preparing film samples for testing?

A: A film cutting template included with the instrument enables standard specimen preparation, ensuring consistent 100 mm x 100 mm samples. Simply cut the film, mount it in the independent test chamber, and follow the prompts on the touch screen LCD for setup.

Q: How can I retrieve and manage the test data?

A: Test results can be stored on the instrument's built-in memory or exported easily via USB. Additionally, RS232 and USB interfaces enable integration with external computers or data systems for further analysis or record-keeping.

Q: What are the main benefits of using this testing instrument?

A: Key benefits include high accuracy and fast response times, programmable environmental controls, compliance with international standards, user-friendly touch screen operation, and robust data handling, all enhancing efficiency and reliability in barrier property analysis for packaging materials.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.