Product Details:

  • Interface Type RS232/USB output
  • Measuring Range 0.01 - 10,000 cc/m24h
  • Temperature Room temperature to 50C
  • Operating Voltage 220V
  • Display Type Digital LCD display
  • Gas Pressure 0.4-0.6 MPa
  • Power Supply AC 220V, 50 Hz
  • Click to View more
X

Testing and Measuring Barrier Performance in Milk Powder Packaging Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Testing and Measuring Barrier Performance in Milk Powder Packaging Product Specifications

  • 220V
  • Room temperature to 50C
  • Barrier Performance Tester
  • 50 Hz
  • Automatic
  • 108 mm 108 mm
  • 0.01 cc/m24h
  • AC 220V, 50 Hz
  • 0.4-0.6 MPa
  • Digital LCD display
  • RS232/USB output
  • 150 mm
  • 0.01 - 10,000 cc/m24h
  • Barrier performance measurement of flexible packaging films
  • 600 mm
  • 60 kg
  • 0.01 - 10,000 cc/m24h (selectable)
  • Milk powder packaging permeability and barrier testing
  • Automatic temperature and humidity control
  • Bench-top
  • 1-3 specimens simultaneously
  • < 2 s
  • 10-500 mm/min (adjustable)
  • 700 mm
  • Continuous operation
  • 0.001 cc/m24h
  • Microcomputer control
  • Standard 6 mm quick connector
  • 20% - 90% RH (non-condensing)

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Accurate Barrier Testing for Packaging Assurance

Ensure your milk powder packaging meets rigorous quality benchmarks with our Barrier Performance Tester. Employing differential pressure and coulometric sensor methods, it measures permeability to oxygen and water vapor. Automatic calibration and adjustable parameters provide versatile, repeatable results, all displayed on a digital LCD for easy monitoring. With robust memory, your facility can store and manage up to 1,000 test results, supporting consistent product excellence.


Compliant and User-Friendly Design

Designed to meet GB, ISO, and ASTM international standards, this tester is ideal for manufacturers, exporters, and suppliers. The intuitive, multi-language interface simplifies operation for teams worldwide. Auto-calibration, overload protection, and continuous operation streamline your laboratory workflow, while comprehensive data connectivity ensures all results are easily exported and documented.

FAQ's of Testing and Measuring Barrier Performance in Milk Powder Packaging:


Q: How does the Barrier Performance Tester evaluate milk powder packaging?

A: The equipment uses differential pressure and coulometric sensor methods to accurately measure the transmission rates of oxygen and water vapor through packaging films. This enables precise barrier assessment in compliance with GB, ISO, and ASTM standards.

Q: What are the benefits of using auto-calibration and built-in safety features?

A: Auto-calibration ensures fast, accurate results without manual recalibration, while overload and leak protection safeguard both samples and users, maintaining operational integrity and reducing downtime.

Q: When should I use the specimen cutting template for sample preparation?

A: The specimen cutting template should be used before beginning a test to ensure each packaging film sample is consistently sized (108 mm 108 mm). This consistency contributes to reliable and reproducible results.

Q: Where is the best place to install the Barrier Performance Tester?

A: Install the tester in a dust-free laboratory or a dedicated quality control environment. This ensures optimum performance and protects sensitive sensor components from environmental contaminants.

Q: What is the process for exporting test data from the device?

A: After completing tests, data can be exported via USB or RS232 interfaces. The built-in interface allows efficient transfer to a computer for further analysis, reporting, or documentation.

Q: How can the equipment's memory and operation language features support daily workflow?

A: The tester's memory stores up to 1,000 test records, enabling traceability and batch comparison. Its multi-language support (English, Chinese, etc.) ensures ease of use for diverse teams, minimizing training requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.