Product Description
Product Featuresnote1
OTR/WVTR tested in One Instrument
- OTR WVTR mode, OTR mode and WVTR mode are available for selection.
- OTR and WVTR tests can be automatically completed for each sample mounting.
- Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.
Coulometric Oxygen Sensor
- The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
- Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
- Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
- Over limit alarm and automatic protection.
Infrared Moisture Sensor
- The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
- Designed according to ASTM F1249.
- Longer service life, non-consumable.
- Over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
- In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
High Efficiency Three-cell
- Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
- Three samples can be tested at the same time under the same conditions, with independent tests data.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
- Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
- Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
- Wide temperature range, allowing the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).
Testing Principle
The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.
Reference Standards
ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Applications
| Applications |
- Films
The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
|
- Sheets
The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Specifications
Table 1: Test Parameters Note2
| Parameter/Model |
Model C403H |
| OTR Test Range |
cc/(m2day) (Standard area 50cm2) |
0.01 200 |
| cc/(m2day) (MASK area 5cm2) |
0.2 2000 (Optional) |
| cc/(m2day) (MASK area 1cm2) |
1 10000 (Optional) |
| OTR Resolution |
cc/(m2day) |
0.0001 |
| OTR Repeatability |
cc/(m2day) |
0.01 or 1%, whichever is greater |
| WVTR Test Range |
g/(m2day) (Standard area 50cm2) |
0.005 40 |
| g/(m2day) (MASK area 5cm2) |
0.2 400 (Optional) |
| g/(m2day) (MASK area 1cm2) |
1 2000 (Optional) |
| WVTR Resolution |
g/(m2day) |
0.0001 |
| WVTR Repeatability |
g/(m2day) |
0.005 or 2%, whichever is greater |
| Temperature range |
C |
15 - 50 5 60 (Customized) |
| Temperature fluctuation |
C |
0.05 |
| Humidity range |
%RH (Within standard temperature range) |
0%, 5 - 902% |
| Extended functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Note3 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 test chambers |
| Specimen Size |
4.4 x 4.4i1411.2cm11.2cm) |
| Specimen Thickness |
120 Mili143mmi14 |
| Standard Test Area |
50 cm2 |
| Carrier Gas |
99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope) |
| Carrier Gas Pressure |
40.6 PSI / 280 kPa |
| Port Size |
1/8 inch metal tubing |
| Power Supply |
120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14 |
| Instrument Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Net weight |
220Lbsi14100kgi14 |
Configurations
- Standard Configurations
- Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
- Optional Parts
- GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
- Remarks
- 1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.
Preserve Freshness with Advanced Barrier TestingMaintaining the freshness and flavor of tea and coffee heavily relies on packaging's ability to prevent the ingress of oxygen and moisture. Our Barrier Property Tester provides accurate measurement of these properties, ensuring your packaging meets premium quality standards. By using advanced sensor technology and auto-calibration, you can trust the results to help you optimize packaging and extend shelf life.
Comprehensive Standards ComplianceThe tester fully aligns with widely recognized methods such as ASTM D3985, ISO 15105-2, and ASTM F1249, enabling reliable and consistent results. With multipurpose capabilities, it helps tea and coffee producers guarantee compliance with international packaging specifications, ensuring products remain competitive in global markets.
User-Friendly Automated OperationThis instrument features a digital LCD touch display, USB/RS232 interfaces, automatic calibration, and data export functions. The benchtop design, microprocessor control, and easy sample preparation ensure smooth lab operations. Automatic error detection and precise ambient compensation contribute to reliable long-term use with minimal manual intervention.
FAQ's of Testing Oxygen and Moisture Barrier Properties for Maintaining freshness in tea and coffee packaging:
Q: How does the Barrier Property Tester measure oxygen and moisture permeability in tea and coffee packaging?
A: The equipment uses a coulometric sensor for oxygen detection and an infrared sensor for water vapor analysis. Packaging samples are placed in the 18 L test chamber, and the machine automatically monitors gas transmission rates, providing data in compliance with ASTM D3985, ISO 15105-2, and ASTM F1249 standards.
Q: What are the benefits of using this tester for tea and coffee packaging?
A: By accurately measuring barrier properties, this tester helps determine the effectiveness of packaging in preserving aroma and freshness. The results can guide improvements in material selection and process control, directly impacting shelf life and consumer satisfaction.
Q: When should packaging manufacturers use this Barrier Property Tester?
A: Manufacturers should use this equipment during quality control checks, new material evaluations, packaging design validation, or prior to batch production. Routine testing helps identify performance issues early and ensure ongoing compliance with food packaging standards.
Q: Where can the Barrier Property Tester be deployed?
A: This benchtop unit is ideal for labs focused on packaging research, quality assurance departments, and production facilities in the tea and coffee industry. Its multi-gas compatibility and specimen versatility suit a wide range of barrier testing scenarios.
Q: What is the process for testing a sample with this equipment?
A: Up to three specimens measuring 100 mm x 100 mm are placed inside the chamber. After selecting the test parameters on the LCD touch display, the instrument performs automatic calibration, commences the test, and records data. Test conditions like humidity and temperature are adjustable for different requirements.
Q: What makes the testing process reliable and user-friendly?
A: Automatic calibration, digital display, USB data export, adjustable test speeds, and built-in alarms for over-range and faults ensure accurate, traceable results with minimal operator effort. The auto ambient air compensation further reduces environmental influences.
Q: How does adherence to international standards benefit exporters and suppliers?
A: Compliance with ASTM D3985, ISO 15105-2, and ASTM F1249 ensures the test results are globally recognized, facilitating smoother trade, regulatory acceptance, and enhanced trust in packaging quality for international markets.