Call Us
Send Inquiry Send SMS    Call Me Free
Evaluating Oxygen Barrier Performance in Chocolate Packaging

Evaluating Oxygen Barrier Performance in Chocolate Packaging

50000 USD ($)/Set

Product Details:

  • Mounting Type Benchtop
  • Humidity 20% RH - 90% RH
  • Max Height 450 mm
  • Power Supply AC 220 V 10%, 50 Hz
  • Measuring Range 0.01~10,000 cc/m24h0.1MPa
  • Automation Grade Automatic
  • Gas Pressure 0.1 ~ 0.6 MPa
  • Click to View more
X

Evaluating Oxygen Barrier Performance in Chocolate Packaging Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Evaluating Oxygen Barrier Performance in Chocolate Packaging Product Specifications

  • 15C - 40C
  • Oxygen Transmission Rate (OTR) Analyzer
  • Microprocessor based digital control
  • Within 30 seconds
  • Max. 100 mm
  • 0.01 - 10,000 cc/m24h0.1MPa
  • 1 - 3
  • Touch Screen LCD
  • Approx. 45 kg
  • 0.01~10,000 cc/m24h0.1MPa
  • 100 mm to 300 mm
  • Automatic
  • Adjustable 5 mm/min to 500 mm/min
  • AC 220 V 10%, 50 Hz
  • Customizable
  • 450 mm
  • 20% RH - 90% RH
  • Benchtop
  • 50 / 60 Hz
  • USB 2.0, RS232
  • AC 220V 10V, 50/60 Hz
  • High sensitivity sensor, automatic temperature and humidity control, data logging capability
  • 2% of reading
  • 6 mm
  • Evaluating Oxygen Barrier Performance in Chocolate Packaging
  • 50 mm x 50 mm, circular or rectangular
  • 0.1 ~ 0.6 MPa
  • Quality control in chocolate packaging
  • 0.001 cc/m24h0.1MPa

Product Description

Product FeaturesNote1

Coulometric Oxygen Sensor

  • The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
  • Designed according to ASTM D3985 with absolute value and no need to calibrate.
  • Super long service life, three times longer than traditional Coulometric oxygen sensor.
  • Functions of over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
  • In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

Effective Three-Cell

  • Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
  • Three samples are tested at the same time under the same condition, and the data are independent.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
  • Safe Performance: the instrument uses global famous brand with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
  • Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
  • Ultra wide test range, meet the barrier test (customized) of various materials.
  • Ultra wide temperature range, meet the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).

Testing Principle

The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.

Reference Standards

ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

Test Applications

Applications
  • Films
    The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
  • Sheet
    The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Parameters

Table 1: Test Parameters Note2

Parameters/Model C203H
Test Scope cc/(m2day) (standard area 50cm2) 0.01i200
0.005i200 (optional)
cc/(m2day) (standard area 50cm2) 0.01i400000i14Customizei14
cc/(m2day) (MASK area 5cm2) 0.12000 (optional)
cc/(m2day) (MASK area 1cm2) 0.510000 (optional)
Resolving Power cc/(m2day) 0.0001
Repeatability cc/(m2day) 0.01 or1%, whichever is greater
Temperature Range  15i50
560 (customized)
Temperature Fluctuation 0.05
Humidity Range %Rh (within standard temperature range) O2: 0%i145i901%
Carrier Gas: 0%, 5i902%
Extended Functions GP-01 Gas Purification Unit Optional
DataShieldTM Data Shield Note 3 Optional
GMP Computer System Requirements Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 sets
Sample Size 4.4 x 4.4i1411.2cm11.2cmi14
Sample Thickness 120 Mili143mmi14
Standard Test Area 50cm2
Gas Specification 99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer)
Air Source Pressure 40.6 PSI / 280 kPa
Interface Size 1 / 8 "metal tube
Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Power Supply 120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two)
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs(100kg)

Table 3: Product Configuration

Standard Configuration Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm
Options Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements
DataShieldTM Data ShieldNote3
Remarks The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.



Precise Measurement for Superior Chocolate Packaging

Ensure the highest protection for your chocolate products with an OTR Analyzer engineered for rigorous oxygen barrier assessment. Equipped with a coulometric sensor and global standard compliance, the device delivers rapid, accurate results. Automatic sample conditioning and calibration streamline testing, while stainless steel construction guarantees long-term durability. By leveraging microprocessor-driven controls, operators achieve consistent, repeatable outcomes-ideal for quality control environments.


User-Friendly Operation and Data Management

This OTR Analyzer features an intuitive touch screen LCD interface with automatic humidity and temperature control, making it suitable for various laboratory settings. Data is exportable via USB or RS232-the tested parameters are instantly available for quality documentation or further analysis on your PC. Automatic calibration and easy specimen mounting simplify the user experience, while built-in safety features minimize operational risks.

FAQ's of Evaluating Oxygen Barrier Performance in Chocolate Packaging:


Q: How does the OTR Analyzer measure the oxygen barrier performance in chocolate packaging?

A: The analyzer assesses oxygen infiltration by utilizing ASTM D3985 / ISO 15105-2 test methods and a coulometric sensor, quantifying the rate of oxygen transmission through chocolate packaging materials under controlled temperature and humidity conditions.

Q: What is the process for calibrating and conditioning samples on this equipment?

A: Calibration is automatic using standard films, ensuring reliable results. Samples are conditioned with an automatic pre-conditioning module before testing, allowing for accurate and consistent measurements on up to three specimens simultaneously.

Q: When should I use this device during the chocolate packaging production process?

A: It is advisable to use the OTR Analyzer during both development and quality control stages to ensure packaging meets industry oxygen barrier standards prior to product shipment or storage.

Q: Where can I access the test results, and in what formats can I export them?

A: Test results are displayed on the touch screen LCD and can be exported directly to a PC via USB or RS232 interface, facilitating comprehensive reporting and data analysis.

Q: What oxygen test range and sample sizes does this analyzer support?

A: The analyzer covers a measuring range from 0.01 to 10,000 cc/m224h0.1MPa, accommodating circular or rectangular specimens sized 50 mm x 50 mm and allowing for up to three samples per test cycle.

Q: What safety and compliance features does the analyzer offer?

A: The system incorporates a pressure relief valve and overheat protection, and all components are designed to comply with global food packaging standards, ensuring safe and reliable operation.

Q: What benefits does using this OTR Analyzer provide for chocolate packaging manufacturers?

A: Manufacturers gain precise, fast oxygen permeability data, enabling improved quality assurance, product shelf-life optimization, and compliance with regulatory standards-all while enjoying automation, ease of use, and robust data handling.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.