Call Us
Send Inquiry Send SMS
Accurate aluminum plastic composite panel thickness measurement

Accurate aluminum plastic composite panel thickness measurement

50000 USD ($)/Set

Product Details:

  • Response Time 0.5 seconds
  • Features Automatic calibration, real-time digital readout, error detection
  • Specimen Size 50 mm x 120 mm
  • Interface Type RS232/USB
  • Frequency 50/60 Hz
  • Equipment Type Aluminum-Plastic Composite Panel Thickness Measurement
  • Application Thickness testing of composite panels
  • Click to View more
X

Accurate aluminum plastic composite panel thickness measurement Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Accurate aluminum plastic composite panel thickness measurement Product Specifications

  • High-resolution digital
  • Semi-automatic
  • 0.5-0.8 MPa
  • 85% RH
  • 35 kg
  • Bench-top
  • Laboratory and industrial testing
  • 500 N
  • 220V AC 10%, 50/60 Hz
  • 0-20 mm
  • 0.01 mm
  • 120 mm
  • 250 mm
  • 150 mm max
  • 1 to 3
  • Aluminum alloy frame: 120 HB
  • Digital microprocessor
  • 220V AC
  • 6 mm air inlet
  • 0 to 20 mm
  • 0.001 mm
  • 10C to 35C
  • Thickness testing of composite panels
  • Aluminum-Plastic Composite Panel Thickness Measurement
  • 50/60 Hz
  • 0.5 seconds
  • 50 mm/min adjustable
  • RS232/USB
  • 50 mm x 120 mm
  • Automatic calibration, real-time digital readout, error detection

Product Description

Features

Professional

With innovative research and development, Labthink C640 Thickness Tester uses high precision displacement sensor, supported by scientific structure and professional control technology, which makes C640 greatly improved in stability, repeatabilityNote1 and accuracy.

  • The instrument conforms to standards for mechanical contact method. The pressure foot can be lifted and lowered automatically, which can minimize the errors caused by human operation.
  • Contacting time and test speed can be set as required. Customization is available for multiple contact areas and pressures, which can meet the requirements for various test conditions.
  • Manual and automatic test modes can be selected by the users
  • Calibration of multiple points can improve the linearity of the whole test range, which ensures the accuracy of measured results.
  • Standard gauge block is available for fast calibration

High Efficiency

The instrument is featured with high efficiency and automatic design of structure, which minimize the human operation in measuring process. Intelligent controlling and data processing functions make it easy and reliable for test operation and data processing.

  • Parameter program function enables the user to save all test parameters in a file so that those parameters can be applied directly for the same tests next time, which can help the user save time and minimize the error when inputting parameters manually.
  • Test results include maximum value, minimum value, average value and standard variation, which can be displayed to the user directly.
  • Result comparison function can help the user in evaluation of results.
  • Auto sampling function (optional), feeding space, feeding speed, measure points can be set as required, which ensures the accuracy of multiple successive points measurement.

Intelligent

The instrument is embedded with Labthinks latest operating software, which is featured with user-friendly interface, intelligent data processing, strict user management and secure data storage. It also supports Labthink exclusive DataShieldTM (Optional) which provides the users with safe and reliable management of test data and test reports.

  • Test data can be displayed in various forms including curves and data list
  • Test data will be saved and encrypted in a unique way so that all the test information will be saved securely and reliably and protected from being tampered
  • Various forms of test data can be searched, exported and printed out

Note: The described features should be in line with Table 1: Test Parameters.
Note1: The Repeatability refers to the repeatability within the test range.

Test Principle

The pre-conditioned specimen is placed on a flat test plane, the pressure foot which is paralleled to the test plane will drop down on the upper surface of the specimen with certain pressure applied on. The displacement sensor with the pressure foot will detect the space between the upper and lower surface of the specimen, which is the thickness of the specimen.

Test Standards

ISO 4593, ISO 534, ASTM D6988, ASTM F2251, GB/T 6672, GB/T 451.3, TAPPI T411, BS 2782-6, DIN 53370, ISO 3034, ISO 12625-3, ISO 5084, ASTM D374, ASTM D1777, ASTM D3652, GB/T 6547, GB/T 24218.2, FEFCO No 3, EN 1942, JIS K6250, JIS K6783, JIS Z1702

Note: The described test standards should be in line with Table 1: Test Parameters.

Applications

Basic Applications
  • Films and Sheeting
    Thickness measurement of various plastic films, sheeting, and diaphragms, etc.
  • Paper
    Thickness measurement of various paper, paper board and composite paper board, etc.
Extended Applications
  • Metal Pieces & Silicon Wafers
    Thickness measurement of silicon wafers, foils and various metal pieces, etc.
  • Corrugated Paperboard
    Thickness measurement of corrugated paperboard
  • Textiles
    Thickness measurement of textiles including woven fabrics, knitted fabrics, coated fabrics
  • Non-woven Fabrics
    Thickness measurement of non-woven fabrics e.g. baby diapers, sanitary napkins and medical masks, etc.
  • Other Materials
    Thickness measurement of solid insulation materials, adhesive tapes, earthwork synthetic materials and rubbers, etc.

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C640M C640H
Test Range (Standard) mm 0 2 0 2
Resolution m 0.1 0.1
RepeatabilityNote3 m 0.8 0.4
Test Range (Optional 1) mm 0 6 0 6
Test Range (Optional 2) mm 0 12 0 12
Feeding Space mm 0 1000 (Adjustable)
Feeding Speed mm/s 1.5 80 (Adjustable)
Additional Functions Auto Sampler Optional Optional
DataShieldTM Note2
Optional Optional

Table 2: Technical Specifications

Measuring Method Mechanical Contact Method
Test Pressure & Contact AreaNote3 Film: 17.51 KPa, 50 mm2
Paper: 1001 KPa (Standard) / 501kPa (Optional), 200mm2
Instrument Dimension 370 mm (L) x 350 mm (W) x 410 mm (H)
Net Weight 26kg

Note1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions. For extended applications, customization is available to meet the special testing requirements.
Note2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note3: Test pressure and contact area can be selected for paper or film. There are two options for test pressure for paper, i.e. 100kPa (standard) and 50kPa(optional). For other test pressure and contact area or curved pressure foot, customizations are available.



Exceptional Measurement Precision

Achieve unparalleled accuracy in thickness testing for aluminum-plastic composite panels with a 0.001 mm display resolution and 0.01 mm accuracy. The system's precision linear encoder and digital microprocessor deliver consistent, real-time measurements with rapid 0.5-second response. This ensures reliable data for quality assurance in both laboratory and industrial settings.


Robust Design and User-Friendly Operation

Crafted from high-strength anodized aluminum, this instrument is engineered for longevity and stability. Touch panel controls, bilingual menu options, and pushbuttons simplify operation, while automatic calibration streamlines setup. Its bench-top mounting design with carrying handles supports easy portability, ideal for diverse testing environments.


Streamlined Data Management and Compliance

Keep your results organized with storage for up to 200 test sets and seamless data transfer through RS232/USB interfaces. RoHS and CE certifications affirm the equipment's commitment to safety and environmental regulations, while emergency stop and overload protection features further safeguard users and samples during operation.

FAQ's of Accurate aluminum plastic composite panel thickness measurement:


Q: How does the device achieve such high accuracy in panel thickness measurement?

A: The instrument employs a contact-type displacement measurement principle combined with a precision linear encoder and high-resolution digital display, enabling a measurement resolution of up to 0.001 mm and an accuracy of 0.01 mm.

Q: What are the sample preparation and testing requirements?

A: Specimens should be manually cut to a size of 50 mm x 120 mm with a 3 to 5 mm edge clearance on the aluminum-plastic composite panel. The machine can test 1 to 3 specimens at a time, with a maximum test width of 150 mm and stroke of 120 mm.

Q: When should I perform calibration on the equipment?

A: It is recommended to calibrate the device every 6 months to maintain optimal measurement accuracy. Automatic calibration functionality is integrated for convenience.

Q: Where can this thickness gauge be used?

A: The bench-top design with carrying handles allows for portability, making it suitable for laboratory and industrial environments requiring precise thickness measurement of composite panels. Its operation is reliable within 10C to 35C and 85% relative humidity.

Q: What is the process for operating the thickness measurement device?

A: The operator prepares the sample manually and positions it correctly with the required edge clearance. Test conditions are set using the intuitive touch panel or pushbuttons. Measurement is then conducted at an adjustable speed (up to 50 mm/min), with data automatically recorded and displayed in real time.

Q: How does the equipment enhance daily usage and user safety?

A: Automatic calibration, error detection, overload protection, and an emergency stop function ensure accuracy and safety. The digital microprocessor offers smooth semi-automatic control, while the data storage capacity and bilingual interface support convenient daily operations.

Q: What benefits does this instrument provide for quality control?

A: The device delivers highly repeatable and accurate thickness readings with fast digital output. Its robust design, environmental compliance certifications, and streamlined data management collectively support enhanced productivity and reliable quality assurance for manufacturers and exporters.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Thickness Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.