Applications
Principle
Firstly submerge the specimen in the water within the vacuum chamber, and then evacuate the vacuum chamber to form differential pressure between the inside and outside of specimen. The leakage property could be obtained by observing the steady progression of bubbles from the specimen and how the specimen expands and restores to its original shape after vacuum release.
Specifications
Specifications | MFY-01 |
---|---|
Vacuum Degree | 0 ~ -90 KPa |
Accuracy | 1% FS |
Vacuum Chamber Effective Sizes | Φ270 mm x 210 mm (H) (standard) |
Φ360 mm x 585 mm (H) (optional) | |
Φ460 mm x 330 mm (H) (optional) | |
Note: customization is available for other sizes | |
Gas Supply Pressure | 0.7 MPa (outside of supply scope) |
Port Size | Ф6 mm PU Tubing |
Instrument Dimension | 300 mm (L) x 380 mm (W) x 450 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 12 kg |
![]() |
LABTHINK INSTRUMENTS CO. LTD.